A Miniaturized, Programmable Pacemaker for Long-Term Studies in the Mouse
- 9 November 2018
- journal article
- review article
- Published by Wolters Kluwer Health in Circulation Research
- Vol. 123 (11) , 1208-1219
Abstract
Rationale:: Cardiac pacing is a critical technology for the treatment of arrhythmia and heart failure. The impact of specific pacing strategies on myocardial function is an area of intense research and high clinical significance. Mouse models have proven extremely useful for probing mechanisms of heart disease, but there is currently no reliable technology for long-term pacing in the mouse. Objective:: We sought to develop a device for long-term pacing studies in mice. We evaluated the device for (1) treating third-degree atrioventricular block after macrophage depletion, (2) ventricular pacing-induced cardiomyopathy, and (3) high-rate atrial pacing. Methods and Results:: We developed a mouse pacemaker by refashioning a 26 mm×6.7 mm clinical device powered by a miniaturized, highly efficient battery. The electrode was fitted with a single flexible lead, and custom software extended the pacing rate to up to 1200 bpm. The wirelessly programmable device was implanted in the dorsal subcutaneous space of 39 mice. The tunneled lead was passed through a left thoracotomy incision and attached to the epicardial surface of the apex (for ventricular pacing) or the left atrium (for atrial pacing). Mice tolerated the implantation and both long-term atrial and ventricular pacing over weeks. We then validated the pacemaker’s suitability for the treatment of atrioventricular block after macrophage depletion in Cd11b DTR mice. Ventricular pacing increased the heart rate from 313±59 to 550 bpm ( P <0.05). In addition, we characterized tachypacing-induced cardiomyopathy in mice. Four weeks of ventricular pacing resulted in reduced left ventricular function, fibrosis, and an increased number of cardiac leukocytes and endothelial activation. Finally, we demonstrated the feasibility of chronic atrial pacing at 1200 bpm. Conclusions:: Long-term pacing with a fully implantable, programmable, and battery-powered device enables previously impossible investigations of arrhythmia and heart failure in the mouse.Keywords
This publication has 31 references indexed in Scilit:
- A Fully Implantable Pacemaker for the Mouse: From Battery to Wireless PowerPLOS ONE, 2013
- Early ion-channel remodeling and arrhythmias precede hypertrophy in a mouse model of complete atrioventricular blockJournal of Molecular and Cellular Cardiology, 2011
- Transforming growth factor (TGF)-β signaling in cardiac remodelingJournal of Molecular and Cellular Cardiology, 2011
- Animal models for atrial fibrillation: clinical insights and scientific opportunitiesEP Europace, 2009
- Large Animal Models of Heart FailureCirculation: Heart Failure, 2009
- The canine model with chronic, complete atrio-ventricular blockPharmacology & Therapeutics, 2008
- ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesCirculation, 2008
- Osteopontin Expression Is Required for Myofibroblast DifferentiationCirculation Research, 2008
- Differential regional gene expression from cardiac dyssynchrony induced by chronic right ventricular free wall pacing in the mousePhysiological Genomics, 2006
- Ionic Mechanisms of Acquired QT Prolongation and Torsades de Pointes in Rabbits With Chronic Complete Atrioventricular BlockCirculation, 2002