Standoff LIBS detection of explosive residues behind a barrier
Authors:
- 8 July 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 24 (8) , 1123-1126
Abstract
Development studies reveal that explosives detection is possible behind a barrier placed between a target and a standoff LIBS sensor. Barriers such as polymethylmethacrylate (PMMA) and a variety of glasses have been tested. Results for the detection of organic (DNT, TNT, C4 and H15) and inorganic (sodium chlorate) explosive residues placed up to 30 m from the sensor are presented. The standoff experiments have been evaluated in the emission (studies on laser beam transmission sent by the sensor) and collection (studies on plasma light emission collected by the sensor) channels. These experiments open wide perspectives for the detection of IEDs (improvised explosive devices) through windows located, for instance, inside vehicles, industrial warehouses and buildings where explosive residues have been produced, handled, stored or prepared.Keywords
This publication has 5 references indexed in Scilit:
- UV gated Raman spectroscopy for standoff detection of explosivesOptical Materials, 2008
- Libraries for spectrum identification: Method of normalized coordinates versus linear correlationSpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Strategies for residue explosives detection using laser-induced breakdown spectroscopyJournal of Analytical Atomic Spectrometry, 2007
- Test of a stand-off laser-induced breakdown spectroscopy sensor for the detection of explosive residues on solid surfacesJournal of Analytical Atomic Spectrometry, 2005
- Standoff Detection of High Explosive Materials at 50 Meters in Ambient Light Conditions Using a Small Raman InstrumentApplied Spectroscopy, 2005