Abstract
Purpose: In civil engineering construction, the reinforced concrete (RC) structure is generally used and exposed to fatigue loading as it is in service. The assessment of the RC structure is required to maintain the service life of the structure.Design/methodology/approach: This paper presents the behaviour of RC beam specimens under increasing maximum fatigue loading until failure. Simultaneously the acoustic emission (AE) was recorded. Twelve phases of maximum fatigue loading at Stage 1 and Stage 2 were applied to the beam with the frequency of 1 Hz and 5,000 load cycles were applied for each load phase. Two AE parameters were analysed and discussed, namely average frequency and rise angle value at CH4 and CH5.Findings: The results found that the load and crack are closely related to the AE activities in the RC beam specimen when subjected to increasing fatigue loading.Originality/value: To investigate the AE characteristics of RC beam specimens subjected to 12 phases of maximum fatigue loading using the average frequency and rise angle value.Keywords
This publication has 13 references indexed in Scilit:
- Theoretical modelling and acoustic emission monitoring of RC beams strengthened with UHPCConstruction and Building Materials, 2018
- Effect of propagation distance on acoustic emission fracture mode classification in textile reinforced cementConstruction and Building Materials, 2017
- Fatigue Crack Inspection and Acoustic Emission Characteristics of Precast RC Beam under Repetition LoadingApplied Mechanics and Materials, 2015
- Diagnostic of fatigue damage severity on reinforced concrete beam using acoustic emission techniqueEngineering Failure Analysis, 2014
- Acoustic emission signal for fatigue crack classification on reinforced concrete beamConstruction and Building Materials, 2013
- Damage classification in reinforced concrete beam by acoustic emission signal analysisConstruction and Building Materials, 2013
- Recommendation of RILEM TC 212-ACD: acoustic emission and related NDE techniques for crack detection and damage evaluation in concrete*Materials and Structures, 2010
- Compressive failure in concrete of recycled aggregate by acoustic emissionConstruction and Building Materials, 2007
- Acoustic Emission Monitoring and Analysis of Glass Fiber-Reinforced Composites Bridge DecksJournal of Bridge Engineering, 2005
- Evaluation of fatigue damage in reinforced concrete slab by acoustic emissionNDT & E International, 2001