Altering Overuse of Cardiac Telemetry in Non–Intensive Care Unit Settings by Hardwiring the Use of American Heart Association Guidelines

Authors:

Abstract
Arrhythmia detection is reported to affect the clinical management of care in 3.4% to 12.7% of patients.1 The American Heart Association’s (AHA’s)2 published recommendations addressing the use of non–intensive care unit (non-ICU) cardiac telemetry stratify patients into 3 categories: cardiac telemetry is indicated, may provide benefit, or is unlikely to provide benefit. Clinical-effectiveness studies of implementing these guidelines have either reported the use of labor-intensive strategies3 or nonsustained decreases in non-ICU cardiac telemetry use.4 Various efforts to reduce the perceived overuse of cardiac telemetry at Christiana Care Health System, a 1100-bed tertiary care system, were unsuccessful. In August 2012 we convened a team to increase the appropriate use of non-ICU cardiac telemetry through the integration of AHA guidelines into our electronic ordering system (EOS). This effort was validated in March 2013 when non-ICU use of cardiac telemetry appeared on the Society of Hospital Medicine’s top 5 list for the Choosing Wisely campaign.5