A leadless pacemaker in the real‐world setting: Patient profile and performance over time
Authors:
Open Access
- 8 January 2023
- journal article
- research article
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (1) , 1-9
Abstract
Background: While prior Micra trials demonstrated a high implant success rate and favorable safety and efficacy results, changes in implant populations and safety over time is not well studied. The objective of this analysis was to report the performance of Micra in European and Middle Eastern patients and compare to the Micra Investigational Device Exemption (IDE) and Micra Post Approval Registry (PAR) studies.Methods: The prospective, single‐arm Micra Acute Performance European and Middle Eastern (MAP EMEA) registry was designed to further study the performance of Micra in patients from EMEA. The primary endpoint was to characterize acute (30‐day) major complications. Electrical performance was analyzed. The major complication rate through 12 months was compared with the IDE and PAR studies.Results: The MAP EMEA cohort (n = 928 patients) had an implant success rate of 99.9% and were followed for an average of 9.7 ± 6.5 months. Compared to prior studies, MAP EMEA patients were more likely to have undergone dialysis and have a condition which precluded the use of a transvenous pacemaker (p < .001). Within 30 days of implantation, the MAP EMEA cohort had a major complication rate of 2.59%. Mean pacing thresholds were low and stable through 12 months (0.61 ± 0.40 V at 0.24 ms at implant and 12 months). Through 12 months post‐implantation, the major complication rate for MAP EMEA was not significantly different from IDE (p = .56) or PAR (p = .79).Conclusion: Despite patient differences over time, the Micra leadless pacemaker was implanted with a high success rate and low complication rate, in‐line with prior reports.Keywords
Funding Information
- Medtronic
This publication has 20 references indexed in Scilit:
- How to Implant a Leadless Pacemaker With a Tine‐Based FixationJournal of Cardiovascular Electrophysiology, 2016
- Safety evaluation of a leadless transcatheter pacemaker for magnetic resonance imaging useHeart Rhythm, 2016
- UK Renal Registry 18th Annual Report: Chapter 12 Epidemiology of Reported Infections amongst Patients Receiving Dialysis for Established Renal Failure in England 2013 to 2014: a Joint Report from Public Health England and the UK Renal RegistryNephron, 2016
- A Leadless Intracardiac Transcatheter Pacing SystemThe New England journal of medicine, 2016
- Cardiac implantable electronic device infection in patients with end-stage renal diseaseHeart Rhythm, 2015
- Percutaneous Implantation of an Entirely Intracardiac Leadless PacemakerThe New England journal of medicine, 2015
- Clinical Presentation and Outcomes of Cardiovascular Implantable Electronic Device Infections in Hemodialysis PatientsAmerican Journal of Kidney Diseases, 2014
- Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in DenmarkEuropean Heart Journal, 2013
- Incidence and predictors of short- and long-term complications in pacemaker therapy: The FOLLOWPACE studyHeart Rhythm, 2012
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009