Start-up of membrane bioreactor and hybrid moving bed biofilm reactor–membrane bioreactor: kinetic study
Authors:
- 8 August 2015
- journal article
- research article
- Published by IWA Publishing in Water Science & Technology
- Vol. 72 (11) , 1948-1953
Abstract
A hybrid moving bed biofilm reactor–membrane bioreactor (hybrid MBBR-MBR) system was studied as an alternative solution to conventional activated sludge processes and membrane bioreactors. This paper shows the results obtained from three laboratory-scale wastewater treatment plants working in parallel in the start-up and steady states. The first wastewater treatment plant was a MBR, the second one was a hybrid MBBR-MBR system containing carriers both in anoxic and aerobic zones of the bioreactor (hybrid MBBR-MBRa), and the last one was a hybrid MBBR-MBR system which contained carriers only in the aerobic zone (hybrid MBBR-MBRb). The reactors operated with a hydraulic retention time of 30.40 h. A kinetic study for characterizing heterotrophic biomass was carried out and organic matter and nutrients removals were evaluated. The heterotrophic biomass of the hybrid MBBR-MBRb showed the best kinetic performance in the steady state, with yield coefficient for heterotrophic biomass = 0.30246 mg volatile suspended solids per mg chemical oxygen demand, maximum specific growth rate for heterotrophic biomass = 0.00308 h−1 and half-saturation coefficient for organic matter = 3.54908 mg O2 L−1. The removal of organic matter was supported by the kinetic study of heterotrophic biomass.Keywords
This publication has 13 references indexed in Scilit:
- Comparative kinetics of hybrid and pure moving bed reactor-membrane bioreactorsEcological Engineering, 2014
- Influence of sludge retention time and temperature on the sludge removal in a submerged membrane bioreactor: Comparative study between pure oxygen and air to supply aerobic conditionsJournal of Environmental Science and Health, Part A, 2013
- Comparative kinetic study between moving bed biofilm reactor-membrane bioreactor and membrane bioreactor systems and their influence on organic matter and nutrients removalBiochemical Engineering Journal, 2013
- Modeling simultaneous nitrification and denitrification (SND) in a fluidized bed biofilm reactorApplied Mathematical Modelling, 2012
- Modelling respirometric tests for the assessment of kinetic and stoichiometric parameters on MBBR biofilm for municipal wastewater treatmentEnvironmental Modelling & Software, 2010
- Comparison between hybrid moving bed biofilm reactor and activated sludge system: a pilot plant experimentWater Science & Technology, 2010
- Impact of aeration rates on particle colloidal fraction in the biofilm membrane bioreactor (BF-MBR)Desalination, 2008
- Optimizing and modelling nitrogen removal in a new configuration of the moving-bed biofilm reactor processWater Science & Technology, 2007
- The development of a biofilm membrane bioreactorDesalination, 2007
- Advanced compact wastewater treatment based on coagulation and moving bed biofilm processesWater Science & Technology, 2000