A 750-MHz electronically tunable resonator using microstrip line couplers for electron paramagnetic resonance imaging of a mouse tumor-bearing leg
- 23 August 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 65 (00189294) , 1
Abstract
Objective: The purpose of this work was to develop an electronically tunable resonator operating at 750 MHz for continuous-wave electron paramagnetic resonance (CW-EPR) imaging of a mouse tumor-bearing leg. Methods: The resonator had a multi-coil parallel-gap structure with a sample space of 16 mm in diameter and 20 mm in length. Microstrip line couplers were used in conjunction with varactor diodes to enable resonance frequency adjustment and to reduce the nonlinear effects of the varactor diodes. The resonator was modeled by the finite-element method and a microwave circuit simulation was performed to clarify its radiofrequency characteristics. Results : A tunable resonator was evaluated in terms of its resonance frequency, tunable frequency band, and conversion efficiency of the RF magnetic field. The developed resonator provided a tunable frequency band of 4 MHz at a central frequency of 747 MHz and a conversion efficiency of 34 μT/W 1/2 . To demonstrate the application of this tunable resonator to EPR imaging, three-dimensional EPR images of a sample solution and a mouse tumor-bearing leg were obtained. Conclusion: The developed tunable resonator satisfied our initial requirements for in vivo EPR imaging and may be able to be further improved using the present finite-element and circuit models if any problems arise during future practical applications. Significance: This work may help to promote EPR imaging of tumor-bearing mice in cancer-related studies.Keywords
Funding Information
- Japan Society for the Promotion of Science (26249057, 16K12852)
This publication has 37 references indexed in Scilit:
- Noninvasive mapping of the redox status in septic mouse by in vivo electron paramagnetic resonance imagingMagnetic Resonance Imaging, 2012
- Low-field paramagnetic resonance imaging of tumor oxygenation and glycolytic activity in miceJournal of Clinical Investigation, 2008
- Electron Paramagnetic Resonance Oxygen Images Correlate Spatially and Quantitatively with Oxylite Oxygen MeasurementsClinical Cancer Research, 2006
- Decoupling of automatic control systems in a continuous-wave electron paramagnetic resonance spectrometer for biomedical applicationsNMR in Biomedicine, 2004
- Application of continuous‐wave EPR spectral‐spatial image reconstruction techniques for in vivo oxymetry: Comparison of projection reconstruction and constant‐time modalitiesMagnetic Resonance in Medicine, 2003
- Characteristics of an electronically tunable surface-coil-type resonator for L-band electron paramagnetic resonance spectroscopyReview of Scientific Instruments, 2001
- Visualization of Eddy-current losses in L-band ESR imagingJournal of Magnetic Resonance (1969), 1992
- A radiofrequency ESR spectrometer for in vivo imagingJournal of Magnetic Resonance (1969), 1991
- The loop-gap resonator: a new microwave lumped circuit ESR sample structureJournal of Magnetic Resonance (1969), 1982
- Split-ring resonator for use in magnetic resonance from 200–2000 MHzReview of Scientific Instruments, 1981