Validity of continuous glucose monitoring for categorizing glycemic responses to diet: implications for use in personalized nutrition

Authors:

Abstract
Continuous glucose monitor (CGM) devices enable characterization of individuals’ glycemic variation. However, there are concerns about their reliability for categorizing glycemic responses to foods that would limit their potential application in personalized nutrition recommendations. We aimed to evaluate the concordance of 2 simultaneously worn CGM devices in measuring postprandial glycemic responses. Within ZOE PREDICT (Personalised Responses to Dietary Composition Trial) 1, 394 participants wore 2 CGM devices simultaneously [n = 360 participants with 2 Abbott Freestyle Libre Pro (FSL) devices; n = 34 participants with both FSL and Dexcom G6] for ≤14 d while consuming standardized (n = 4457) and ad libitum (n = 5738) meals. We examined the CV and correlation of the incremental area under the glucose curve at 2 h (glucoseiAUC0–2 h). Within-subject meal ranking was assessed using Kendall τ rank correlation. Concordance between paired devices in time in range according to the American Diabetes Association cutoffs (TIRADA) and glucose variability (glucose CV) was also investigated. The CV of glucoseiAUC0–2 h for standardized meals was 3.7% (IQR: 1.7%–7.1%) for intrabrand device and 12.5% (IQR: 5.1%–24.8%) for interbrand device comparisons. Similar estimates were observed for ad libitum meals, with intrabrand and interbrand device CVs of glucoseiAUC0–2 h of 4.1% (IQR: 1.8%–7.1%) and 16.6% (IQR: 5.5%–30.7%), respectively. Kendall τ rank correlation showed glucoseiAUC0–2h-derived meal rankings were agreeable between paired CGM devices (intrabrand: 0.9; IQR: 0.8–0.9; interbrand: 0.7; IQR: 0.5–0.8). Paired CGMs also showed strong concordance for TIRADA with a intrabrand device CV of 4.8% (IQR: 1.9%–9.8%) and an interbrand device CV of 3.2% (IQR: 1.1%–6.2%). Our data demonstrate strong concordance of CGM devices in monitoring glycemic responses and suggest their potential use in personalized nutrition. This trial was registered at clinicaltrials.gov as NCT03479866.
Funding Information
  • Wellcome Trust
  • Medical Research Council
  • Versus Arthritis
  • Chronic Disease Research Foundation
  • NIHR
  • CRN
  • Biotechnology and Biological Sciences Research Council (BB/NO12739/1)
  • MGH (R35 CA253185)
  • PWF
  • European Research Council (CoG-2015_681742_NASCENT)
  • Swedish Research Council
  • Novo Nordisk Foundation
  • Swedish Foundation for Strategic Research
  • National Institute for Health Research
  • European Union
  • Biomedical Research Centre
  • American Diabetes Association (#7-21-JDFM-005)
  • NIH (P30 DK40561)

This publication has 30 references indexed in Scilit: