Validity of continuous glucose monitoring for categorizing glycemic responses to diet: implications for use in personalized nutrition
Open Access
- 4 February 2022
- journal article
- research article
- Published by Elsevier in The American Journal of Clinical Nutrition
- Vol. 115 (6) , 1569-1576
Abstract
Continuous glucose monitor (CGM) devices enable characterization of individuals’ glycemic variation. However, there are concerns about their reliability for categorizing glycemic responses to foods that would limit their potential application in personalized nutrition recommendations. We aimed to evaluate the concordance of 2 simultaneously worn CGM devices in measuring postprandial glycemic responses. Within ZOE PREDICT (Personalised Responses to Dietary Composition Trial) 1, 394 participants wore 2 CGM devices simultaneously [n = 360 participants with 2 Abbott Freestyle Libre Pro (FSL) devices; n = 34 participants with both FSL and Dexcom G6] for ≤14 d while consuming standardized (n = 4457) and ad libitum (n = 5738) meals. We examined the CV and correlation of the incremental area under the glucose curve at 2 h (glucoseiAUC0–2 h). Within-subject meal ranking was assessed using Kendall τ rank correlation. Concordance between paired devices in time in range according to the American Diabetes Association cutoffs (TIRADA) and glucose variability (glucose CV) was also investigated. The CV of glucoseiAUC0–2 h for standardized meals was 3.7% (IQR: 1.7%–7.1%) for intrabrand device and 12.5% (IQR: 5.1%–24.8%) for interbrand device comparisons. Similar estimates were observed for ad libitum meals, with intrabrand and interbrand device CVs of glucoseiAUC0–2 h of 4.1% (IQR: 1.8%–7.1%) and 16.6% (IQR: 5.5%–30.7%), respectively. Kendall τ rank correlation showed glucoseiAUC0–2h-derived meal rankings were agreeable between paired CGM devices (intrabrand: 0.9; IQR: 0.8–0.9; interbrand: 0.7; IQR: 0.5–0.8). Paired CGMs also showed strong concordance for TIRADA with a intrabrand device CV of 4.8% (IQR: 1.9%–9.8%) and an interbrand device CV of 3.2% (IQR: 1.1%–6.2%). Our data demonstrate strong concordance of CGM devices in monitoring glycemic responses and suggest their potential use in personalized nutrition. This trial was registered at clinicaltrials.gov as NCT03479866.Keywords
Funding Information
- Wellcome Trust
- Medical Research Council
- Versus Arthritis
- Chronic Disease Research Foundation
- NIHR
- CRN
- Biotechnology and Biological Sciences Research Council (BB/NO12739/1)
- MGH (R35 CA253185)
- PWF
- European Research Council (CoG-2015_681742_NASCENT)
- Swedish Research Council
- Novo Nordisk Foundation
- Swedish Foundation for Strategic Research
- National Institute for Health Research
- European Union
- Biomedical Research Centre
- American Diabetes Association (#7-21-JDFM-005)
- NIH (P30 DK40561)
This publication has 30 references indexed in Scilit:
- Bread Affects Clinical Parameters and Induces Gut Microbiome-Associated Personal Glycemic ResponsesCell Metabolism, 2017
- Exercise and Postprandial Glycemic Control in Type 2 DiabetesCurrent Diabetes Reviews, 2016
- Personalized Nutrition by Prediction of Glycemic ResponsesCell, 2015
- Randomized clinical trial of the efficacy and safety of insulin glargine vs. NPH insulin as basal insulin for the treatment of glucocorticoid induced hyperglycemia using continuous glucose monitoring in hospitalized patients with type 2 diabetes and respiratory diseaseDiabetes Research and Clinical Practice, 2015
- Rate-of-Change Dependence of the Performance of Two CGM Systems During Induced Glucose SwingsJournal of Diabetes Science and Technology, 2015
- Time Lag of Glucose From Intravascular to Interstitial Compartment in Type 1 DiabetesJournal of Diabetes Science and Technology, 2014
- Evaluation of the Performance of a Novel System for Continuous Glucose MonitoringJournal of Diabetes Science and Technology, 2013
- Performance Evaluation of Three Continuous Glucose Monitoring Systems: Comparison of Six Sensors Per Subject in ParallelJournal of Diabetes Science and Technology, 2013
- Glycemic Variability: The Third Component of the Dysglycemia in Diabetes. Is it Important? How to Measure it?Journal of Diabetes Science and Technology, 2008
- Activation of Oxidative Stress by Acute Glucose Fluctuations Compared With Sustained Chronic Hyperglycemia in Patients With Type 2 DiabetesJAMA, 2006