Abstract
Background: For people with type 1 diabetes (T1D), ensuring fast and effective recovery from hypoglycemia while avoiding posthypoglycemic hyperglycemia (rebound hyperglycemia, RH) can be challenging. The objective of this study was to investigate the frequency of RH across different treatment modalities and its impact on glycemic control. Methods: This cross-sectional real-world study included adults with T1D using continuous glucose monitoring and attending the outpatient clinic at Steno Diabetes Center Copenhagen. RH was defined as ≥1 sensor glucose value (SG) >10.0 mmol/L (180 mg/dL) starting within 2 h of an antecedent SG P < 0.0001). Overall, severity of RH was inversely associated with more advanced technology ( P < 0.001) and inversely associated ( P < 0.001) with time in target range (TIR). Conclusions: Groups with insulin suspension features experienced the highest frequency of RH; however, AID users tended to experience shorter and less severe RH events. The association between the severity of RH events and TIR suggests that RH should be assessed and used in the guidance of hypoglycemia management.