Stimulation latency and comparison of cycling regimens in women using sacral neuromodulation
- 1 February 2016
- journal article
- clinical trial
- Published by Wiley in Neurourology and Urodynamics
- Vol. 36 (2) , 486-489
Abstract
Aims In this two-part study, we sought to define how long sacral neuromodulation users with overactive bladder should trial a new setting before attributing symptoms to that setting. Subsequently, we evaluated patient preferences of variable stimulation regimens. Methods In the initial phase of this prospective pilot study, participants' devices were turned off and later reactivated; time to symptom recurrence and resolution were recorded. In phase two, participants trialed four settings in a masked fashion with random order. After unmasking, participants chose their preferred setting and were followed 1 year. Results Twelve subjects completed phase one. With the device off, the mean time to symptom recurrence was 11.25 days. Mean time to symptom regression following reactivation was 6.42 days. Combined, the 90th percentile was 15 days for symptoms to reflect the device's new setting. Among 23 women completing part two, the most popular setting at the time of unmasking was a 1-hr on, 2-hr off cycled setting chosen by 7 (30%) participants. According to published estimates of battery longevity, 14 (61%) participants chose a more energy-conserving setting at the time of unmasking. The mean difference in estimated battery longevity between the chosen and baseline regimens was 14.5 months. These gains diminished in the following year with clinical changes in device settings by patients and providers. Conclusions Sacral neuromodulation patients should allow a 2-week trial before attributing symptoms to a new setting. With additional information, many opt for energy-conserving settings. A 1-hr on, 2-hr off regimen warrants further study. Neurourol. Urodynam.Keywords
This publication has 3 references indexed in Scilit:
- Diagnosis and Treatment of Overactive Bladder (Non-Neurogenic) in Adults: AUA/SUFU Guideline AmendmentJournal of Urology, 2015
- How Does Sacral Modulation Work Best? Placement and Programming Techniques to Maximize EfficacyCurrent Urology Reports, 2011
- Procedural techniques in sacral nerve modulationInternational Urogynecology Journal, 2010