In Vivo Imaging Evaluation of Fluorescence Intensity at Tail Emission of Near-Infrared-I (NIR-I) Fluorophores in a Porcine Model
Authors:
- María Rita Rodríguez-LunaMRMaría Rita Rodríguez-Luna
- Nariaki OkamotoNONariaki Okamoto
- Mahdi Al-TaherMAMahdi Al-Taher
- Deborah S. KellerDeborah S. Keller
- Lorenzo CinelliLCLorenzo Cinelli
- Anila Hoskere AshokaAAAnila Hoskere Ashoka
- Andrey S. KlymchenkoAKAndrey S. Klymchenko
- Jacques MarescauxJacques Marescaux
- Michele DianaMichele Diana
Open Access
Abstract
Over the last decade fluorescence-guided surgery has been primarily focused on the NIR-I window. However, the NIR-I window has constraints, such as limited penetration and scattering. Consequently, exploring the performance of NIR-I dyes at longer wavelengths (i.e., the NIR-II window) is crucial to expanding its application. Two fluorophores were used in three pigs to identify the mean fluorescence intensity (MFI) using two commercially available NIR-I and NIR-II cameras. The near-infrared coating of equipment (NICE) was used to identify endoluminal surgical catheters and indocyanine green (ICG) for common bile duct (CBD) characterization. The NIR-II window evaluation showed an MFI of 0.4 arbitrary units (a.u.) ± 0.106 a.u. in small bowel NICE-coated catheters and an MFI of 0.09 a.u. ± 0.039 a.u. in gastric ones. In CBD characterization, the ICG MFI was 0.12 a.u. ± 0.027 a.u., 0.18 a.u. ± 0.100 a.u., and 0.22 a.u. ± 0.041 a.u. at 5, 35, and 65 min, respectively. This in vivo imaging evaluation of NIR-I dyes confirms its application in the NIR-II domain. To the best of our knowledge, this is the first study assessing the MIF of NICE in the NIR-II window using a commercially available system. Further comparative trials are necessary to determine the superiority of NIR-II imaging systems.Keywords
Funding Information
- ARC Foundation for Cancer Research
This publication has 27 references indexed in Scilit:
- Improving quality of science through better animal welfare: the NC3Rs strategyLab Animal, 2017
- Strategic options towards an affordable high-performance infrared camera2016
- Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental modelBritish Journal of Surgery, 2015
- A review of performance of near-infrared fluorescence imaging devices used in clinical studiesBritish Journal of Radiology, 2015
- Image-guided cancer surgery using near-infrared fluorescenceNature Reviews Clinical Oncology, 2013
- An Experimental Study to Evaluate the Fluobeam 800 Imaging System for Fluorescence-Guided Lymphatic Imaging and Sentinel Node BiopsySurgical Innovation, 2012
- Intraoperative assessment of biliary anatomy for prevention of bile duct injury: a review of current and future patient safety interventionsSurgical Endoscopy, 2011
- Video-assisted thoracoscopic indocyanine green fluorescence imaging system shows sentinel lymph nodes in non–small-cell lung cancerThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Improving Bioscience Research Reporting: The ARRIVE Guidelines for Reporting Animal ResearchPLOS Biology, 2010
- In vivo near-infrared fluorescence imagingCurrent Opinion in Chemical Biology, 2003