Modular multilevel TMS device with wide output range and ultrabrief pulse capability for sound reduction
- 17 March 2022
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026008
Abstract
Objective. This article presents a novel transcranial magnetic stimulation (TMS) pulse generator with a wide range of pulse shape, amplitude, and width. Approach. Based on a modular multilevel TMS (MM-TMS) topology we had proposed previously, we realized the first such device operating at full TMS energy levels. It consists of ten cascaded H-bridge modules, each implemented with insulated-gate bipolar transistors, enabling both novel high-amplitude ultrabrief pulses as well as pulses with conventional amplitude and duration. The MM-TMS device can output pulses including up to 21 voltage levels with a step size of up to 1100 V, allowing relatively flexible generation of various pulse waveforms and sequences. The circuit further allows charging the energy storage capacitor on each of the ten cascaded modules with a conventional TMS power supply. Main results . The MM-TMS device can output peak coil voltages and currents of 11 kV and 10 kA, respectively, enabling suprathreshold ultrabrief pulses (>8.25 μ s active electric field phase). Further, the MM-TMS device can generate a wide range of near-rectangular monophasic and biphasic pulses, as well as more complex staircase-approximated sinusoidal, polyphasic, and amplitude-modulated pulses. At matched estimated stimulation strength, briefer pulses emit less sound, which could enable quieter TMS. Finally, the MM-TMS device can instantaneously increase or decrease the amplitude from one pulse to the next in discrete steps by adding or removing modules in series, which enables rapid pulse sequences and paired-pulse protocols with variable pulse shapes and amplitudes. Significance. The MM-TMS device allows unprecedented control of the pulse characteristics which could enable novel protocols and quieter pulses.Keywords
All Related Versions
Funding Information
- National Institute of Mental Health of the National Institutes of Health (R01MH111865 and RF1MH124943)
This publication has 47 references indexed in Scilit:
- Pulse width dependence of motor threshold and input–output curve characterized with controllable pulse parameter transcranial magnetic stimulationClinical Neurophysiology, 2013
- Analysis and Optimization of Pulse Dynamics for Magnetic StimulationPLOS ONE, 2013
- Muscle force development after low‐frequency magnetic burst stimulation in dogsMuscle & Nerve, 2012
- The number of full-sine cycles per pulse influences the efficacy of multicycle transcranial magnetic stimulationBrain Stimulation, 2012
- Repetitive transcranial magnetic stimulator with controllable pulse parametersJournal of Neural Engineering, 2011
- Late Cortical Disinhibition in Human Motor Cortex: A Triple-Pulse Transcranial Magnetic Stimulation StudyJournal of Neurophysiology, 2010
- Bidirectional long‐term motor cortical plasticity and metaplasticity induced by quadripulse transcranial magnetic stimulationThe Journal of Physiology, 2008
- Prediction of Myelinated Nerve Fiber Stimulation Thresholds: Limitations of Linear ModelsIEEE Transactions on Biomedical Engineering, 2004
- Modeling the turn-off of IGBT's in hard- and soft-switching applicationsIEEE Transactions on Electron Devices, 1997
- The influence of stimulus type on the magnetic excitation of nerve structuresElectroencephalography and Clinical Neurophysiology, 1990