Two-View Topogram-Based Anatomy-Guided CT Reconstruction for Prospective Risk Minimization
Authors:
Preprint
Abstract
To facilitate a prospective estimation of CT effective dose and risk minimization process, a prospective spatial dose estimation and the known anatomical structures are expected. To this end, a CT reconstruction method is required to reconstruct CT volumes from as few projections as possible, i.e. by using the topograms, with anatomical structures as correct as possible. In this work, an optimized CT reconstruction model based on a generative adversarial network (GAN) is proposed. The GAN is trained to reconstruct 3D volumes from an anterior-posterior and a lateral CT projection. To enhance anatomical structures, a pre-trained organ segmentation network and the 3D perceptual loss are applied during the training phase, so that the model can then generate both organ-enhanced CT volume and the organ segmentation mask. The proposed method can reconstruct CT volumes with PSNR of 26.49, RMSE of 196.17, and SSIM of 0.64, compared to 26.21, 201.55 and 0.63 using the baseline method. In terms of the anatomical structure, the proposed method effectively enhances the organ shape and boundary and allows for a straight-forward identification of the relevant anatomical structures. We note that conventional reconstruction metrics fail to indicate the enhancement of anatomical structures. In addition to such metrics, the evaluation is expanded with assessing the organ segmentation performance. The average organ dice of the proposed method is 0.71 compared with 0.63 in baseline model, indicating the enhancement of anatomical structures.Keywords
All Related Versions
This publication has 12 references indexed in Scilit:
- Patient‐specific radiation risk‐based tube current modulation for diagnostic CTMedical Physics, 2022
- Real‐time estimation of patient‐specific dose distributions for medical CT using the deep dose estimationMedical Physics, 2022
- Reconstruction of three‐dimensional tomographic patient models for radiation dose modulation in CT from two scout views using deep learningMedical Physics, 2022
- Reconstruction of 3D CT from A Single X-ray Projection View Using CVAE-GAN2021
- CCX-rayNet: A Class Conditioned Convolutional Neural Network For Biplanar X-Rays to CT Volume2021
- CT-ORG, a new dataset for multiple organ segmentation in computed tomographyScientific Data, 2020
- X2CT-GAN: Reconstructing CT From Biplanar X-Rays With Generative Adversarial Networks2019
- Low-Dose CT Image Denoising Using a Generative Adversarial Network With Wasserstein Distance and Perceptual LossIEEE Transactions on Medical Imaging, 2018
- The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT ScansMedical Physics, 2011
- Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadaversEuropean Radiology, 1999