Interobserver Reliability of Neck-Mobility Measurement by Means of the Flock-of-Birds Electromagnetic Tracking System
Authors:
- Nienke AssinkNANienke Assink
- Gert J.D. BergmanGBGert J.D. Bergman
- Bianca KnoesterBKBianca Knoester
- Jan C. WintersJWJan C. Winters
- Pieter U. DijkstraPDPieter U. Dijkstra
- Klaas PostemaKPKlaas Postema
- 1 July 2005
- journal article
- research article
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 28 (6) , 408-413
Abstract
To establish the interobserver reliability for measuring neck mobility in human subjects by means of an electromagnetic tracking device, the Flock-of-Birds system. Two observers independently and in random order assessed the cervical range-of-motion in 30 subjects with a dysfunction in the neck and shoulder region (symptomatic subjects) and 30 subjects without known pathology (asymptomatic subjects). Measurements included rotation in neutral position, in flexed position and in extended position, flexion-extension, and lateral bending (all active and passive). Reliability was analyzed by intraclass correlation coefficient (ICC) and agreement by limits of agreement and percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees. For asymptomatic subjects, the ICC varied from 0.57 to 0.85, and the limits of agreement varied between 14.5 degrees and 27.0 degrees. The percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees ranged from 31% to 57%, 58% to 90%, and 78% to 93%, respectively. For symptomatic subjects, the ICC varied from 0.36 to 0.91, and the limits of agreement varied between 9.6 degrees and 37.8 degrees. The percentage of paired observations within 5 degrees, 10 degrees, and 15 degrees ranged from 17% to 60%, 33% to 93%, and 50% to 97%, respectively. Despite the use of a standardized protocol and a sophisticated measurement system, the interobserver reliability of neck mobility was variable in quality, with reliability being good in rotation in neutral position, flexion-extension, and lateral bending.Keywords
This publication has 11 references indexed in Scilit:
- Neck mobility measurement by means of the ‘Flock of Birds’ electromagnetic tracking systemClinical Biomechanics, 2003
- Groningen Manipulation Study. The effect of manipulation of the structures of the shoulder girdle as additional treatment for symptom relief and for prevention of chronicity or recurrence of shoulder symptoms. Design of a randomized controlled trial within a comprehensive prognostic cohort studyJournal of Manipulative and Physiological Therapeutics, 2002
- `Coupled motions' in cervical spine rotation can be misleading. Comment on V. Feipel, B. Rondelet, J.-P. Le Pallec and M. Rooze. Normal global motion of the cervical spine: an electrogoniometric study. Clin. Biomechanics 1999; 14: 462–470Clinical Biomechanics, 2001
- Biomechanics of the cervical spine. I: Normal kinematicsClinical Biomechanics, 2000
- Assessment of published reliability studies for cervical spine range-of-motion measurement toolsJournal of Manipulative and Physiological Therapeutics, 2000
- Meta-Analysis of Normative Cervical MotionSpine, 1999
- Calibration of the “Flock of Birds” electromagnetic tracking device and its application in shoulder motion studiesJournal of Biomechanics, 1999
- 3D shoulder position measurements using a six-degree-of-freedom electromagnetic tracking deviceClinical Biomechanics, 1998
- Three-Dimensional Analysis of Neck MotionSpine, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986