A detailed IC package numerical model calibration methodology
Authors:
- 1 March 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10652221,p. 65-70
Abstract
Experimentally derived structure functions can be used to provide insights into the thermal resistances and capacitances heat experiences as it travels from a die through and beyond an IC package. A 3D “detailed” numerical model of the package that purports to explicitly represent the internal construction of the package requires material properties and geometric sizes to be accurately specified. A structure function derived from simulating the detailed numerical model can itself be compared to the experimentally derived reference example. Deviations between experimental and numerical SFs indicate error sites within the detailed model and an indication of whether the thermal resistances or thermal capacitances of the numerical would need to be increased or decreased to match the experimentally observed values. Iterative modifications of the detailed model, based on successive structure function comparisons, will achieve a fully calibrated detailed numerical package model.Keywords
This publication has 5 references indexed in Scilit:
- Use Isothermal Surface to Help Understanding the Spatial Representation of Structure FunctionTransactions of The Japan Institute of Electronics Packaging, 2012
- Package Characterization: Simulations or Measurements?2008
- Thermal transient characterization methodology for single-chip and stacked structures2005
- Determining partial thermal resistances with transient measurements, and using the method to detect die attach discontinuities2003
- Identification of RC networks by deconvolution: chances and limitsIEEE Transactions on Circuits and Systems I: Regular Papers, 1998