A precision 3D conformal treatment technique in rats: Application to whole‐brain radiotherapy with hippocampal avoidance
- 24 August 2017
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 44 (11) , 6008-6017
Abstract
Purpose: To develop and validate three‐dimensional (3D) conformal hippocampal sparing whole‐brain radiation therapy (HA‐WBRT) for Wistar rats utilizing precision 3D‐printed immobilization and micro‐blocks. This technique paves the way for future preclinical studies investigating brain treatments that reduce neurotoxicity.Methods and materials: A novel preclinical treatment planning and delivery process was developed to enable precision 3D conformal treatment and hippocampal avoidance capability for the Xrad 225cx small animal irradiator. A range of conformal avoidance plans were evaluated consisting of equiangularly spaced coplanar axial beams, with plans containing 2, 4, 7, and 8 fields. The hippocampal sparing and coverage of these plans were investigated through Monte Carlo dose calculation (SmART‐Plan Xrad 225cx planning system). Treatment delivery was implemented through a novel process where hippocampal block shapes were computer generated from an MRI rat atlas which was registered to on‐board cone beam CT of the rat in treatment position. The blocks were 3D printed with a tungsten‐doped filament at lateral resolution of 80 μm. Precision immobilization was achieved utilizing a 3D‐printed support system which enabled angled positioning of the rat head in supine position and bite block to improve coverage of the central diencephalon. Treatment delivery was verified on rodent‐morphic Presage® 3D dosimeters optically scanned at 0.2‐mm isotropic resolution. Biological verification of hippocampal avoidance was performed with immunohistologic staining.Results: All simulated plans spared the hippocampus while delivering high dose to the brain (22.5–26.2 Gy mean dose to brain at mean hippocampal dose of 7 Gy). No significant improvement in hippocampal sparing was observed by adding beams beyond four fields. Dosimetric sparing of hippocampal region of the four‐field plan was verified with the Presage® dosimeter (mean dose = 9.6 Gy, D100% = 7.1 Gy). Simulation and dosimeter match at distance‐to‐agreement of 2 mm and dose difference of ±3% at 91.7% gamma passing rate (passing criteria of γ < 1). Agreement is less at 1 mm and ±5% at 69.0% gamma passing rate. The four‐field plan was further validated with immunohistochemistry and showed a significant reduction in DNA double‐strand breaks within the spared region compared with whole‐brain irradiated groups (P = 0.021). However, coverage of the whole brain was low at 48.5–57.8% of the volume receiving 30Gy at 7Gy mean hippocampal dose in simulation and 46.7–52.5% in dosimetric measurements. This can be attributed to the shape of the rat hippocampus and the inability of treatment platform to employ non‐coplanar beams.Conclusion: A novel approach for conformal microradiation therapy using 3D‐printing technology was developed, implemented, and validated. A workflow was developed to generate accurate 3D‐printed blocks from registered high‐resolution rat MRI atlas structures. Although hippocampus was spared with this technique, whole‐brain target coverage was suboptimal, indicating that non‐coplanar beams and IMRT capability may be required to meet stringent dose criteria associated with current human RTOG trials.Keywords
Funding Information
- National Institutes of Health (1R35 CA197616)
This publication has 18 references indexed in Scilit:
- Treatment Planning and Delivery of Whole Brain Irradiation with Hippocampal Avoidance in RatsPLOS ONE, 2015
- CogState computerized memory tests in patients with brain metastases: secondary endpoint results of NRG Oncology RTOG 0933Journal of Neuro-Oncology, 2015
- Hippocampus Avoidance Whole-brain Radiation Therapy: A Practical Intensity-modulated Radiation Therapy Planning and Delivery Approach to RTOG 0933Journal of Medical Imaging and Radiation Sciences, 2015
- Investigating the accuracy of microstereotactic‐body‐radiotherapy utilizing anatomically accurate 3D printed rodent‐morphic dosimetersMedical Physics, 2015
- Preservation of Memory With Conformal Avoidance of the Hippocampal Neural Stem-Cell Compartment During Whole-Brain Radiotherapy for Brain Metastases (RTOG 0933): A Phase II Multi-Institutional TrialJournal of Clinical Oncology, 2014
- Development and validation of a treatment planning system for small animal radiotherapy: SmART-PlanRadiotherapy and Oncology, 2013
- Investigating end-to-end accuracy of image guided radiation treatment delivery using a micro-irradiatorPhysics in Medicine & Biology, 2013
- A multidimensional magnetic resonance histology atlas of the Wistar rat brainNeuroImage, 2012
- Commissioning a small‐field biological irradiator using point, 2D, and 3D dosimetry techniquesMedical Physics, 2011
- Intracranial Metastatic Disease Spares the Limbic Circuit: A Review of 697 Metastatic Lesions in 107 PatientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010