Deep learning-based end-to-end automated stenosis classification and localization on catheter coronary angiography
Open Access
- 7 February 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 944135
Abstract
Background: Automatic coronary angiography (CAG) assessment may help in faster screening and diagnosis of stenosis in patients with atherosclerotic disease. We aimed to provide an end-to-end workflow that separates cases with normal or mild stenoses from those with higher stenosis severities to facilitate safety screening of a large volume of the CAG images.Methods: A deep learning-based end-to-end workflow was employed as follows: (1) Candidate frame selection from CAG videograms with Convolutional Neural Network (CNN) + Long Short Term Memory (LSTM) network, (2) Stenosis classification with Inception-v3 using 2 or 3 categories (25%, and/or total occlusion) with and without redundancy training, and (3) Stenosis localization with two methods of class activation map (CAM) and anchor-based feature pyramid network (FPN). Overall 13,744 frames from 230 studies were used for the stenosis classification training and fourfold cross-validation for image-, artery-, and per-patient-level. For the stenosis localization training and fourfold cross-validation, 690 images with > 25% stenosis were used.Results: Our model achieved an accuracy of 0.85, sensitivity of 0.96, and AUC of 0.86 in per-patient level stenosis classification. Redundancy training was effective to improve classification performance. Stenosis position localization was adequate with better quantitative results in anchor-based FPN model, achieving global-sensitivity for left coronary artery (LCA) and right coronary artery (RCA) of 0.68 and 0.70.Conclusion: We demonstrated a fully automatic end-to-end deep learning-based workflow that eliminates the vessel extraction and segmentation step in coronary artery stenosis classification and localization on CAG images. This tool may be useful to facilitate safety screening in high-volume centers and in clinical trial settings.Keywords
All Related Versions
This publication has 28 references indexed in Scilit:
- Vessel extraction in X-ray angiograms using deep learning2016
- Automatic detection of coronary stenosis in X-ray angiography through spatio-temporal tracking2014
- Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 studyEuropean Heart Journal, 2013
- Coronary Anatomy to Predict PhysiologyCirculation: Cardiovascular Imaging, 2013
- Visual-Functional Mismatch Between Coronary Angiography and Fractional Flow ReserveJACC: Cardiovascular Interventions, 2012
- Accurate Coronary Centerline Extraction, Caliber Estimation, and Catheter Detection in AngiographiesIEEE Transactions on Information Technology in Biomedicine, 2012
- Diagnostic performance of combined noninvasive coronary angiography and myocardial perfusion imaging using 320 row detector computed tomography: design and implementation of the CORE320 multicenter, multinational diagnostic studyJournal of Cardiovascular Computed Tomography, 2011
- In Vivo Wall Shear Stress Distribution in the Carotid ArteryCirculation: Cardiovascular Imaging, 2010
- Determination of optimal viewing regions for X-ray coronary angiography based on a quantitative analysis of 3D reconstructed modelsThe International Journal of Cardiovascular Imaging, 2008
- Plaque Composition and its Relationship With Acknowledged Shear Stress Patterns in Coronary ArteriesJACC, 2006