COMSOL-Based Placement Design of Printed Piezoelectric Sensor Labels for Shock Monitoring in Transport Packaging

Authors:
  • YOY. Pawar Omkar
    Y. Pawar Omkar
  • SYSiyoung Yang
    Siyoung Yang
  • SLSooman Lim
    Sooman Lim

Abstract
Printed piezoelectric sensor labels can convert package deformation into electrical signals, but their response depends strongly on where the label is attached to the package surface. In this study, a static-equivalent top-impact placement- screening method was constructed for printed PVDF/carbon nitride nanotube (CNNT) piezoelectric sensor labels on a corrugated transport package. A 200 mm × 120 mm × 100 mm package model was used, and four label regions were compared: central-edge, adjacent, side, and impact-reference positions, using the domain-averaged von Mises stress. The directly impacted label served only as a normalization reference, and results were reported as stress-transfer factors and reference-normalized voltage-equivalent indices rather than measured dynamic voltages. At 40 N, the central-edge, adjacent, and side positions reached stress-transfer factors of 0.6953, 0.6034, and 0.2434, respectively. These factors identify the central-edge region as the most suitable off-impact placement. The framework provides a reproducible way to screen sensor-label positions before dynamic drop testing and full package validation.