Evaluation of Posttetanic Motor Evoked Potentials—The Influences of Repetitive Use, the Residual Effects of Tetanic Stimulation to Peripheral Nerve, and the Variability
Authors:
- Masahiko KawaguchiMKMasahiko Kawaguchi
- Hironobu HayashiHHHironobu Hayashi
- Ryuichi AbeRARyuichi Abe
- Satoki InoueSISatoki Inoue
- Hiroyuki NakaseHNHiroyuki Nakase
- Toshisuke SakakiTSToshisuke Sakaki
- Hitoshi FuruyaHFHitoshi Furuya
- 1 January 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Neurosurgical Anesthesiology
- Vol. 22 (1) , 6-10
Abstract
Recently, we developed a new technique to augment myogenic motor evoked potentials (MEPs), called as posttetanic MEPs (p-MEPs), in which tetanic stimulation is applied to peripheral nerve before transcranial stimulation. However, the data on p-MEPs are limited. This study was conducted; (1) to evaluate the influences of repetitive use of p-MEPs on p-MEP amplitudes, (2) to evaluate the residual effects of use of p-MEPs on subsequent conventional MEPs (c-MEPs), and (3) to compare the variability of p-MEPs with that of c-MEPs. Sixty patients under propofol/fentanyl anesthesia with partial neuromuscular blockade were enrolled. For p-MEP measurements, tetanic stimulation was applied to posterior tibial nerve 1 second before transcranial stimulation. In study 1, p-MEPs were repetitively recorded with intervals of 10 or 60 seconds. In study 2, the amplitudes of c-MEPs recorded 15, 30, 60, and 120 seconds after p-MEP recordings were compared with those of control. In study 3, the coefficients of variation of c-MEP and p-MEP responses were compared. The repetitive use of p-MEP with an interval of 10 seconds, but not 60 seconds, induced a significant reduction of p-MEP amplitude. Amplitudes of c-MEP were significantly increased when applied within 60 seconds after p-MEP recordings. The coefficient of variations of p-MEPs was similar to those of c-MEPs. The results indicated that the amplitudes of p-MEP and c-MEP might be affected when applied with a short interval after p-MEP recording.Keywords
This publication has 18 references indexed in Scilit:
- Evaluation of Reliability of Post-Tetanic Motor-Evoked Potential Monitoring During Spinal Surgery Under General AnesthesiaSpine, 2008
- The Effects of the Neuromuscular Blockade Levels on Amplitudes of Posttetanic Motor-Evoked Potentials and Movement in Response to Transcranial Stimulation in Patients Receiving Propofol and Fentanyl AnesthesiaAnesthesia & Analgesia, 2008
- The Effects of Dexmedetomidine on Myogenic Motor Evoked Potentials in RabbitsAnesthesia & Analgesia, 2007
- The Effects of Xenon on Myogenic Motor Evoked Potentials in Rabbits: A Comparison with Propofol and IsofluraneAnesthesia & Analgesia, 2006
- Intraoperative spinal cord monitoring of motor function with myogenic motor evoked potentials: a consideration in anesthesiaJournal of Anesthesia, 2004
- Within-Patient Variability of Myogenic Motor-Evoked Potentials to Multipulse Transcranial Electrical Stimulation During Two Levels of Partial Neuromuscular Blockade in Aortic SurgeryAnesthesia & Analgesia, 1999
- Influence of Isoflurane on Myogenic Motor Evoked Potentials to Single and Multiple Transcranial Stimuli during Nitrous Oxide/Opioid AnesthesiaNeurosurgery, 1998
- Kinetics of Synaptic Depression and Vesicle Recycling after Tetanic Stimulation of Frog Motor Nerve TerminalsBiophysical Journal, 1998
- Effect of Isoflurane on Motor-evoked Potentials Induced by Direct Electrical Stimulation of the Exposed Motor Cortex with Single, Double, and Triple Stimuli in RatsAnesthesiology, 1996
- Intraoperative Monitoring of Spinal Cord Function: A ReviewActa Orthopaedica, 1993