Abstract
Analysis of transient fluid pressure signals has been investigated as an alternative method of fault detection in pipeline systems and has shown promise in both laboratory and field trials. The advantage of the method is that it can potentially provide a fast and cost effective means of locating faults such as leaks, blockages and pipeline wall degradation within a pipeline while the system remains fully operational. The only requirement is that high speed pressure sensors are placed in contact with the fluid. Further development of the method requires detailed numerical models and enhanced understanding of transient flow within a pipeline where variations in pipeline condition and geometry occur. One such variation commonly encountered is the degradation or thinning of pipe walls, which can increase the susceptible of a pipeline to leak development. This paper aims to improve transient-based fault detection methods by investigating how changes in pipe wall thickness will affect the transient behaviour of a system; this is done through the analysis of laboratory experiments. The laboratory experiments are carried out on a stainless steel pipeline of constant outside diameter, into which a pipe section of variable wall thickness is inserted. In order to detect the location and severity of these changes in wall conditions within the laboratory system an inverse transient analysis procedure is employed which considers independent variations in wavespeed and diameter. Inverse transient analyses are carried out using a genetic algorithm optimisation routine to match the response from a one-dimensional method of characteristics transient model to the experimental time domain pressure responses. The accuracy of the detection technique is evaluated and benefits associated with various simplifying assumptions and simulation run times are investigated. It is found that for the case investigated, changes in the wavespeed and nominal diameter of the pipeline are both important to the accuracy of the inverse analysis procedure and can be used to differentiate the observed transient behaviour caused by changes in wall thickness from that caused by other known faults such as leaks. Further application of the method to real pipelines is discussed.Keywords
This publication has 10 references indexed in Scilit:
- Analysis of transient signals in simple pipeline systems with an extended blockageJournal of Hydraulic Research, 2013
- Determining the Internal Wall Condition of a Water Pipeline in the Field Using an Inverse TransientJournal of Hydraulic Engineering, 2013
- Detection of Distributed Deterioration in Single PipesUsing Transient ReflectionsJournal of Pipeline Systems Engineering and Practice, 2013
- Detection of Local Wall Stiffness Drop in Steel-Lined Pressure Tunnels and Shafts of Hydroelectric Power Plants Using Steep Pressure Wave Excitation and Wavelet DecompositionJournal of Hydraulic Engineering, 2012
- Water and Wastewater Pipe Nondestructive Evaluation and Health Monitoring: A ReviewAdvances in Civil Engineering, 2010
- A selective literature review of transient-based leak detection methodsJournal of Hydro-environment Research, 2009
- Optimal Measurement Site Locations for Inverse Transient Analysis in Pipe NetworksJournal of Water Resources Planning and Management, 2003
- TRANSIENT TURBULENT FRICTION IN SMOOTH PIPE FLOWSJournal of Sound and Vibration, 2003
- Leak Detection and Calibration Using Transients and Genetic AlgorithmsJournal of Water Resources Planning and Management, 2000
- Leaks in Pipe NetworksJournal of Hydraulic Engineering, 1992