The effects of kinesiology taping on experimentally-induced thermal and mechanical pain in otherwise pain-free healthy humans: A randomised controlled repeated-measures laboratory study
Open Access
- 10 December 2019
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (12) , e0226109
Abstract
Kinesiology taping (KT) is used to manage musculoskeletal-related pain. There is a paucity of physiological studies evaluating the effect of KT on stimulus-evoked experimental pain. To investigate the effect of KT (applied to lumbar region) on cutaneous somatosensation to noxious and innocuous stimuli in humans with a non-sensitised normally functioning nociceptive system using quantitative sensory testing (QST). Fifty-four participants were randomised to one of three interventions: (i) KT (ii) standard ‘rigid’ taping (ST) (iii) sham taping (ShT). QST measurements were taken at lumbar sites pre-intervention (T1), during-intervention (T2) and during-intervention (T3) in the following sequence: warm-detection-threshold (WDT), heat-pain-threshold (HTPh), heat-pain-tolerance (HPTo), mechanical-detection-threshold (MDT), mechanical-pain-threshold (MPT) and pressure-pain-threshold (PPT). Mixed ANOVA revealed statistically significant interaction between Intervention and Time on MDT (p < .0005) and MPT (p < .0005) but not on WDT (p = .09), HPTh (p = .09), HPTo (p = .51) and PPT (p = .52) datasets. There was no significant simple main effect of Intervention on MDT at T2 (p = .68) and T3 (p = .24), and MPT at T2 (p = .79) and T3 (p = .54); post-hoc tests found KT and ST groups had higher (but non-significant) MDT and MPT than the ShT group. There was a significant simple main effect of Time on MDT and MPT for KT (p < .0005) and ST (p < .0005) groups; post-hoc tests found significant increases in MDT and MPT at T3 and T2 compared with T1 in both KT and ST groups. There was no significant simple main effect of Time on MDT (p = .13) nor MPT (p = .08) for the ShT group. Taping, irrespective of the elasticity, may modulate cutaneous mechanosensation. KT, ST and ShT seemed to have similar influence on cutaneous thermal and deep pressure nociception.Keywords
Funding Information
- Jane Tomlinson Appeal
This publication has 34 references indexed in Scilit:
- Effect of Kinesio Tape Application on Calf Pain and Ankle Range of Motion in DuathletesJournal of Human Kinetics, 2013
- Human Experimental Pain Models for Assessing the Therapeutic Efficacy of Analgesic DrugsPharmacological Reviews, 2012
- Kinesio Taping in Treatment and Prevention of Sports InjuriesSports Medicine, 2012
- Central sensitization: Implications for the diagnosis and treatment of painPain, 2011
- Nociceptors: the sensors of the pain pathwayJournal of Clinical Investigation, 2010
- Experimental and Clinical Applications of Quantitative Sensory Testing Applied to Skin, Muscles and VisceraThe Journal of Pain, 2009
- Determining heat and mechanical pain threshold in inflamed skin of human subjectsJournal of Visualized Experiments, 2009
- Usefulness and limitations of quantitative sensory testing: Clinical and research application in neuropathic pain statesPain, 2007
- Quantitative sensory testing: a comprehensive protocol for clinical trialsEuropean journal of pain, 2006
- Technology literature review: Quantitative sensory testingMuscle & Nerve, 2004