3D T2-weighted imaging to shorten multiparametric prostate MRI protocols
Open Access
- 13 November 2017
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 28 (4) , 1634-1641
Abstract
Objectives To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. Methods This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35–84 years; mean PSA 7.2 ng/ml, 0.4–31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Results Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580–0.623) and 3D (AUC 0.576–0.629) T2w (p > 0.05, respectively). Conclusions Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. Key points • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.Keywords
Funding Information
- Medical University of Vienna
This publication has 25 references indexed in Scilit:
- Cost-effectiveness of MR Imaging–guided Strategies for Detection of Prostate Cancer in Biopsy-Naive MenRadiology, 2017
- Diagnostic accuracy of multi-parametric MRI and TRUS biopsy in prostate cancer (PROMIS): a paired validating confirmatory studyThe Lancet, 2017
- Dramatic increase in the utilization of multiparametric magnetic resonance imaging for detection and management of prostate cancerAbdominal Radiology, 2016
- Serial Magnetic Resonance Imaging in Active Surveillance of Prostate Cancer: Incremental ValueJournal of Urology, 2016
- Magnetic Resonance Imaging-Guided Prostate Biopsy: Institutional Analysis and Systematic ReviewRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2014
- Endorectal 3D T2-weighted 1mm-slice thickness MRI for prostate cancer staging at 1.5Tesla: Should we reconsider the indirects signs of extracapsular extension according to the D’Amico tumor risk criteria?European Journal of Radiology, 2012
- Prostate Cancer: Comparison of 3D T2-Weighted With Conventional 2D T2-Weighted Imaging for Image Quality and Tumor DetectionAmerican Journal of Roentgenology, 2010
- 2D and 3D T2-weighted MR sequences for the assessment of neurovascular bundle changes after nerve-sparing radical retropubic prostatectomy with erectile function correlationEuropean Radiology, 2008
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluationBritish Journal of Radiology, 2007