Determination of the Charge Collection Efficiency in Neutron Irradiated Silicon Detectors
- 8 December 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 56 (6) , 3828-3833
Abstract
The charge collected from p-type silicon strip sensors irradiated to SuperLHC fluences has been determined with a beta source using fast front-end electronics. The bias voltage dependence of the collected charge and the hit detection efficiency have been measured before and after accelerated annealing. Predictions of the performance at the SuperLHC are derived.Keywords
This publication has 11 references indexed in Scilit:
- Charge collection and capacitance–voltage analysis in irradiated n-type magnetic Czochralski silicon detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Comparing radiation tolerant materials and devices for ultra rad-hard tracking detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Impact of annealing of trapping times on charge collection in irradiated silicon detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- The silicon microstrip sensors of the ATLAS semiconductor trackerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Processing and first characterization of detectors made with high resistivity n- and p-type Czochralski siliconNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Performances of miniature microstrip detectors made on oxygen enriched p-type substrates after very high proton irradiationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Simulation of non-ionising energy loss and defect formation in siliconNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Design and results from the APV25, a deep sub-micron CMOS front-end chip for the CMS trackerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- 3D — A proposed new architecture for solid-state radiation detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- Temperature dependence of the radiation induced change of depletion voltage in silicon PIN detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994