Accuracy of forced oscillation technique to assess lung function in geriatric COPD population
Authors:
Open Access
- 1 May 2016
- journal article
- research article
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. 11 (1) , 1105-1118
Abstract
Introduction: Performing lung function test in geriatric patients has never been an easy task. With well-established evidence indicating impaired small airway function and air trapping in patients with geriatric COPD, utilizing forced oscillation technique (FOT) as a supplementary tool may aid in the assessment of lung function in this population. Aims: To study the use of FOT in the assessment of airflow limitation and air trapping in geriatric COPD patients. Study design: A cross-sectional study in a public hospital in Hong Kong. ClinicalTrials.gov ID: NCT01553812. Methods: Geriatric patients who had spirometry-diagnosed COPD were recruited, with both FOT and plethysmography performed. “Resistance” and “reactance” FOT parameters were compared to plethysmography for the assessment of air trapping and airflow limitation. Results: In total, 158 COPD subjects with a mean age of 71.9±0.7 years and percentage of forced expiratory volume in 1 second of 53.4±1.7 L were recruited. FOT values had a good correlation (r=0.4–0.7) to spirometric data. In general, X values (reactance) were better than R values (resistance), showing a higher correlation with spirometric data in airflow limitation (r=0.07–0.49 vs 0.61–0.67), small airway (r=0.05–0.48 vs 0.56–0.65), and lung volume (r=0.12–0.29 vs 0.43–0.49). In addition, resonance frequency (Fres) and frequency dependence (FDep) could well identify the severe type (percentage of forced expiratory volume in 1 second Conclusion: FOT may act as a simple and accurate tool in the assessment of severity of airflow limitation, small and central airway function, and air trapping in patients with geriatric COPD who have difficulties performing conventional lung function test. Moreover, reactance parameters were better than resistance parameters in correlation with air trapping.Keywords
This publication has 49 references indexed in Scilit:
- Spirometry Use among Older Adults with Chronic Obstructive Pulmonary Disease: 1999–2008Annals of the American Thoracic Society, 2013
- Assessment of Small-Airways Disease Using Alveolar Nitric Oxide and Impulse Oscillometry in Asthma and COPDLung, 2010
- The Aging Immune System and Its Relationship to the Development of Chronic Obstructive Pulmonary DiseaseProceedings of the American Thoracic Society, 2009
- Impulse oscillometry in COPD: Identification of measurements related to airway obstruction, airway conductance and lung volumesRespiratory Medicine, 2009
- [Impulse oscillometry for estimation of airway obstruction].2008
- Worldwide burden of COPD in high- and low-income countries. Part III. Asia-Pacific studies.2008
- Spirometry Utilization for COPDChest, 2007
- Study of respiratory function in the elderly with different nutritional and cognitive status and functional ability assessed by plethysmographic and spirometric parametersArchives of Gerontology and Geriatrics, 2003
- Quality of spirometric performance in older peopleAge and Ageing, 2003
- The diagnostic value of total respiratory impedance by impulse oscillometry in chronic obstructive lung disease.1999