Low-Activity 124I-PET/Low-Dose CT Versus 131I Probe Measurements in Pretherapy Assessment of Radioiodine Uptake in Benign Thyroid Diseases
- 1 June 2014
- journal article
- research article
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 99 (6) , 2138-2145
Abstract
Radioiodine therapy of benign thyroid diseases requires pretherapy assessment of radioactive iodine uptake (RAIU) for reliable therapy planning. Our objective was to assess RAIU by low-activity (124)I-positron emission tomography/low-dose computed tomography ((124)I-PET/CT) in comparison with standard (131)I probe measurements. This prospective comparative study was conducted at the Jena University Hospital, Jena, Germany, in a referral center setting. A total of 79 patients with benign thyroid diseases were screened, 40 of whom met the inclusion criteria (stable TSH, free T3 and free T4 levels; no thyroid-specific medication, no iodine contamination) and 24 of whom agreed to participate by signing an informed consent. All patients received the standard (131)I scintillation probe uptake test 30 hours after administration of 3 MBq (131)I. Seven days later, all patients were subjected to (124)I-PET/CT uptake measurement 30 hours after administration of 1 MBq (124)I. The decay-corrected uptake values of both techniques were compared. Additionally, 3 different volume-of-interest-based evaluation methods in PET/CT (whole neck [WN], automatic isocontour [IC], and manually contoured [MC]) were evaluated. The (131)I probe measurement and (124)I-PET.WN method provided very similar mean RAIU (30.7% ± 10.3%; 31.7% ± 8.9%), resulting in a significant positive correlation (r = 0.93, P < .001). Compared with (124)I-PET.WN, the (124)I-PET.IC (29.8% ± 8.6%) and the (124)I-PET.MC (24.5% ± 7.1%) demonstrated lower uptake values. Using activities as low as 1 MBq, the (124)I-PET.WN method shows a good correlation with conventional (131)I probe measurement. Thus, (124)I-PET/CT is a suitable alternative for pretherapy RAIU evaluations. This may offer potential additional benefits such as PET/ultrasound fusion imaging and CT volumetry.Keywords
This publication has 28 references indexed in Scilit:
- Low-Activity 124I-PET/Low-Dose CT Versus 99mTc-Pertechnetate Planar Scintigraphy or 99mTc-Pertechnetate Single-Photon Emission Computed Tomography of the ThyroidClinical Nuclear Medicine, 2013
- The surgical management of goiter: Part I. preoperative evaluationThe Laryngoscope, 2010
- 124I PET-Based 3D-RD Dosimetry for a Pediatric Thyroid Cancer Patient: Real-Time Treatment Planning and Methodologic ComparisonJournal of Nuclear Medicine, 2009
- Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT systemEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- The diagnostic value of 124I-PET in patients with differentiated thyroid cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Three-dimensional positron emission tomography imaging with 124I and 86YNuclear Medicine Communications, 2006
- Radioiodine therapy in patients with hyperthyroid disorder: standard versus dosimetric activity applicationNuclear Medicine Communications, 2003
- Thyroid Volume Measurement in Patients Prior to Radioiodine Therapy: Comparison Between Three-Dimensional Magnetic Resonance Imaging and UltrasonographyThyroid®, 2002
- Measurement of radiation dose to the thyroid using positron emission tomographyBritish Journal of Radiology, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986