Safety and Effectiveness of Transvenous Lead Extraction in Patients with Infected Cardiac Resynchronization Therapy Devices; Is It More Risky than Extraction of Other Systems?
Open Access
- 10 May 2022
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (10) , 5803
Abstract
Background: Transvenous lead extraction (TLE) in patients with implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices is considered as more risky. The aim of this study was to assess the safety and effectiveness of TLE in patients with infected CRT systems. Methods: Data of 3468 patients undergoing TLE in a single high-volume center in years 2006–2021 were analyzed. The clinical and procedural parameters as well as the efficacy and safety of TLE were compared between patients with infected CRT and pacemakers (PM) and ICD systems. Results: Infectious indications for TLE occurred in 1138 patients, including 150 infected CRT (112 CRT-D and 38 CRT-P). The general health condition of CRT patients was worse with higher Charlson’s comorbidity index. The number of extracted leads was higher in the CRT group, but implant duration was significantly longer in the PM than in the ICD and CRT groups (98.93 vs. 55.26 vs. 55.43 months p < 0.01). The procedure was longer in duration, more difficult, and more complex in patients with pacemakers than in those in the CRT group. The occurrence of major complications and clinical and procedural success as well as procedure-related death did not show any relationship to the type of CIED device. Mortality at more than one-year follow-up after TLE was significantly higher among patients with CRT devices (22.7% vs. 8.7%) than among those in the PM group. Conclusion: Despite the greater burden of lead and comorbidities, the complexity and efficiency of removing infected CRT systems is no more dangerous than removing other infected systems. The duration of the implant seems to play a dominant role.Keywords
This publication has 38 references indexed in Scilit:
- Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paperEP Europace, 2011
- Large, Single‐Center Experience in Transvenous Coronary Sinus Lead Extraction: Procedural Outcomes and Predictors for Mechanical DilatationPacing and Clinical Electrophysiology, 2011
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Pacemaker and ICD lead extraction with electrosurgical dissection sheaths and standard transvenous extraction systems: results of a randomized trialEP Europace, 2007
- Predictors of Sudden Cardiac Death and Appropriate Shock in the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) TrialCirculation, 2006
- Cardiac Resynchronization Therapy for Heart FailureCirculation, 2003
- Nonthoracotomy Implantable Defibrillator Lead Extraction:Pacing and Clinical Electrophysiology, 2003
- Intravascular Extraction of Problematic or Infected Permanent Pacemaker Leads: 1994–1996Pacing and Clinical Electrophysiology, 1999
- Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial11No financial support was received for performing the procedures or collecting the data, or for data analysis.JACC, 1999
- Intravascular Lead Extraction Using Locking Stylets and SheathsPacing and Clinical Electrophysiology, 1990