Continuous-Flow Left Ventricular Assist Device Therapy in Patients With Preoperative Hepatic Failure: Are We Pushing the Limits Too Far?
- 27 October 2014
- journal article
- Published by Wiley in Artificial Organs
- Vol. 39 (4) , 336-342
Abstract
The purpose of this study was to evaluate the effects and outcome of continuous-flow left ventricular assist device (cf-LVAD) therapy in patients with preoperative acute hepatic failure. The study design was a retrospective review of prospectively collected data. Included were 42 patients who underwent cf-LVAD implantation (64.3% HeartMate II, 35.7% HeartWare) between July 2007 and May 2013 with preoperative hepatic failure defined as elevation of greater than or equal to two liver function parameters above twice the upper normal range. Mean patient age was 35 ± 12.5 years, comprising 23.8% females. Dilated cardiomyopathy was present in 92.9% of patients (left ventricular ejection fraction 17.3 ± 5.9%). Mean support duration was 511 ± 512 days (range: 2-1996 days). Mean preoperative laboratory parameters for blood urea nitrogen, serum creatinine, total bilirubin, and alanine aminotransferase were 9.5 ± 5.4 mg/dL, 110.3 ± 42.8 μmol/L, 51.7 ± 38.3 mmol/L, and 242.1 ± 268.6 U/L, respectively. All parameters decreased significantly 1 month postoperatively. The mean preoperative modified Model for Endstage Liver Disease excluding international normalized ratio score was 16.03 ± 5.57, which improved significantly after cf-LVAD implantation to 10.62 ± 5.66 (P < 0.001) at 7 days and 5.83 ± 4.98 (P < 0.001) at 30 days postoperatively. One-year and 5-year survival was 75.9 and 48.1%, respectively. 21.4% of the patients underwent LVAD explantation for myocardial recovery, 16.7% were successfully transplanted, and 7.1% underwent LVAD exchange for device failure over the follow-up period. Patients with preexisting acute hepatic failure are reasonable candidates for cf-LVAD implantation, with excellent rates of recovery and survival, suggesting that cf-LVAD therapy should not be denied to patients merely on grounds of "preoperative elevated liver enzymes/hepatopathy."Keywords
This publication has 20 references indexed in Scilit:
- Hepatic and Renal Function with Successful Long-term Support on a Continuous Flow Left Ventricular Assist DeviceHeart, Lung and Circulation, 2014
- Liver dysfunction as a predictor of outcomes in patients with advanced heart failure requiring ventricular assist device support: Use of the Model of End-stage Liver Disease (MELD) and MELD eXcluding INR (MELD-XI) scoring systemThe Journal of Heart and Lung Transplantation, 2012
- Liver Abnormalities in Cardiac Diseases and Heart FailureInternational Journal of Angiology, 2011
- Model for End-Stage Liver Disease Score Predicts Left Ventricular Assist Device Operative Transfusion Requirements, Morbidity, and MortalityCirculation, 2010
- Renal and Hepatic Function Improve in Advanced Heart Failure Patients During Continuous-Flow Support With the HeartMate II Left Ventricular Assist DeviceCirculation, 2009
- Effects of Centrifugal, Axial, and Pulsatile Left Ventricular Assist Device Support on End-Organ Function in Heart Failure PatientsThe Journal of Heart and Lung Transplantation, 2009
- MELD-XI: A rational approach to “sickest first” liver transplantation in cirrhotic patients requiring anticoagulant therapyLiver Transplantation, 2006
- Model for End-Stage Liver Disease (MELD) Predicts Nontransplant Surgical Mortality in Patients With CirrhosisAnnals of Surgery, 2005
- A model to predict poor survival in patients undergoing transjugular intrahepatic portosystemic shuntsHepatology, 2000
- Importance of preoperative liver function as a predictor of survival in patients supported with Thoratec ventricular assist devices as a bridge to transplantationThe Journal of Thoracic and Cardiovascular Surgery, 1998