Improving Interpretation Consistency of Serum Capillary Electrophoresis by Development of Quantitative Graphic Indexes
Preprint
- 1 November 2024
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Capillary zone electrophoresis-immunosubtraction (CZE-IS) is an essential laboratory test in diagnosing plasma cell neoplasms. However, current interpretation of the test results is subjective. To evaluate CZE-IS in a more precise manner, this study proposed five key indexes, namely sharpness index, light chain index, immunoglobulin G index, immunoglobulin A index, and immunoglobulin M index. The reference intervals of these indexes were established using CZE-IS curve data from a clinical laboratory of a referral medical center. A total of 1000 cases with normal electrophoretic patterns were sampled for reference interval establishment, and additional 20 cases were included for validation. The reference intervals in the γ zone were established: 1–6 (sharpness index), 1.06–2.71 (light chain index), 37–454 (immunoglobulin G index), (-9)–41 (immunoglobulin A index), and (-16)–46 (immunoglobulin M index). For the β2 zone, the reference intervals were 3–17 (sharpness index), 0.44–1.90 (light chain index), (-7)–61 (immunoglobulin G index), 2–117 (immunoglobulin A index), and (-12)–35 (immunoglobulin M index). The diagnostic performance of reference intervals of the proposed indexes in validation ranged from 95% to 100%. CZE-IS indexes provide the objective quantification of key characteristics in CZE-IS curves, and improve the precision of CZE-IS interpretation.Keywords
All Related Versions
This publication has 14 references indexed in Scilit:
- The 5th edition of the World Health Organization Classification of Haematolymphoid Tumours: Lymphoid NeoplasmsLeukemia, 2022
- Assessment of M-protein quantification using capillary electrophoresis and immunosubtraction-based integration in clinical samples with low M-protein concentrationsClinical Biochemistry, 2022
- Achieving Expert-Level Interpretation of Serum Protein Electrophoresis through Deep Learning Driven by Human ReasoningClinical Chemistry, 2021
- The cut-offs for kappa/lambda ratio in bone marrow immunohistochemistry for the diagnosis of multiple myelomaHematology, 2020
- Normal values of the electrocardiogram for ages 16–90 yearsJournal of Electrocardiology, 2014
- Analytical variation in the measurement of serum monoclonal component by capillary electrophoresisClinica Chimica Acta, 2004
- Prospective Study of Serum Protein Capillary Zone Electrophoresis and Immunotyping off Monoclonal Proteins by ImmunosubtractionAmerican Journal of Clinical Pathology, 1998
- Identification of monoclonal proteins in serum: A quantitative comparison of acetate, agarose gel, and capillary electrophoresisElectrophoresis, 1997
- Numerical algorithms for capillary electrophoresisJournal of Chromatography A, 1994
- Influence of Statistical Method Used on the Resulting Estimate of Normal RangeClinical Chemistry, 1971