Organ volume measurements: comparison between MRI and autopsy findings in infants following sudden unexpected death
Authors:
- 23 March 2012
- journal article
- research article
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 97 (6) , F434-F438
Abstract
Objective: To assess the accuracy of a semiautomated 3D volume reconstruction method for organ volume measurement by postmortem MRI. Methods: This prospective study was approved by the institutional review board and the infants' parents gave their consent. Postmortem MRI was performed in 16 infants (1 month to 1 year of age) at 1.5 T within 48 h of their sudden death. Virtual organ volumes were estimated using the Myrian software. Real volumes were recorded at autopsy by water displacement. The agreement between virtual and real volumes was quantified following the Bland and Altman's method. Results: There was a good agreement between virtual and real volumes for brain (mean difference: −0.03% (−13.6 to +7.1)), liver (+8.3% (−9.6 to +26.2)) and lungs (+5.5% (−26.6 to +37.6)). For kidneys, spleen and thymus, the MRI/autopsy volume ratio was close to 1 (kidney: 0.87±0.1; spleen: 0.99±0.17; thymus: 0.94±0.25), but with a less good agreement. For heart, the MRI/real volume ratio was 1.29±0.76, possibly due to the presence of residual blood within the heart. The virtual volumes of adrenal glands were significantly underestimated (p=0.04), possibly due to their very small size during the first year of life. The percentage of interobserver and intraobserver variation was lower or equal to 10%, but for thymus (15.9% and 12.6%, respectively) and adrenal glands (69% and 25.9%). Conclusions: Virtual volumetry may provide significant information concerning the macroscopic features of the main organs and help pathologists in sampling organs that are more likely to yield histological findings.Keywords
This publication has 9 references indexed in Scilit:
- Minimally‐invasive fetal autopsy using magnetic resonance imaging and percutaneous organ biopsies: clinical value and comparison to conventional autopsyUltrasound in Obstetrics & Gynecology, 2011
- CT- and MRI-based volumetry of resected liver specimen: Comparison to intraoperative volume and weight measurements and calculation of conversion factorsEuropean Journal of Radiology, 2010
- Two‐ or three‐dimensional ultrasonography: which is the best predictor of pulmonary hypoplasia?Prenatal Diagnosis, 2010
- Adrenal gland volume measurement in septic shock and control patients: a pilot studyEuropean Radiology, 2010
- A semi-automated method for non-invasive internal organ weight estimation by post-mortem magnetic resonance imaging in fetuses, newborns and childrenEuropean Journal of Radiology, 2009
- Sudden infant death syndrome (SIDS): characteristics of deaths since the fall in SIDS in the French region of Languedoc-RoussillonArchives of Disease in Childhood, 2009
- Postmortem fetal organ volumetry using magnetic resonance imaging and comparison to organ weights at conventional autopsyUltrasound in Obstetrics & Gynecology, 2008
- Le développement de la surrénale humaineAnnales d'Endocrinologie, 2005
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986