Low-cost modified endoscopic vacuum therapy using a triple-lumen tube allows nutrition and drainage for treatment of an early post–bariatric surgery leak
- 9 August 2021
- journal article
- editorial
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (07) , E376-E377
Abstract
Leaks after laparoscopic sleeve gastrectomy (LSG) occur in up to 5 % of patients, with mortality rates approaching 4 % [1]. Among available therapies for leaks after bariatric surgery, endoscopic approaches have been shown to be safe and effective. Tissue sealants, cap-mounted clips, suturing, stents, a cardiac septal defect occluder, septotomy, endoscopic internal drainage with double pigtails, and endoscopic vacuum therapy (EVT) are the forefront of the therapeutic endoscopic arsenal [2] [3]. However, an individualized approach is needed to determine the best endoscopic treatment strategy for a given patient. In this video, we describe the successful treatment of a LSG leak using low-cost modified EVT. A 30-year-old woman with class II obesity developed fever, nausea, and abdominal pain 14 days after LSG. Computed tomographic scan revealed a leak associated with a small contained collection adjacent to the staple line of the proximal stomach (angle of His). Underwater esophagogastroduodenoscopy was performed without air insufflation to avoid disrupting the collection ([Fig. 1]). The patient was treated with modified EVT using widely available triple-lumen tubing to allow for nutrition using the jejunal tube and EVT using the fenestrated portion of the tube ([Video 1]). The procedure was well tolerated and the patient remained on enteral nutrition as well as taking a liquid diet on the day following the procedure. External drainage was not required. After 15 days, imaging demonstrated resolution of the leak ([Fig. 2]), and the modified EVT system was removed ([Fig. 3]). Video 1 Low-cost modified endoscopic vacuum therapy with a triple-lumen tube. In summary, endoscopic drainage with this low-cost, modified EVT is a highly effective and safe technique for leaks [4] [5]. Furthermore, EVT obviates the need for external drainage and employs widely available materials. Ultimately, this low-cost modified EVT allows for nutrition and drainage with a single tube through the nares, enabling decreased procedure times, longer periods between EVT system exchanges, and fewer adverse events. Endoscopy_UCTN_Code_TTT_1AO_2AI Publication Date: 09 August 2021 (online) © 2021. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, GermanyKeywords
This publication has 5 references indexed in Scilit:
- Customized bariatric stents for sleeve gastrectomy leak: are they superior to conventional esophageal stents? A systematic review and proportion meta-analysisSurgical Endoscopy, 2020
- Endoscopic vacuum therapy versus endoscopic stenting for upper gastrointestinal transmural defects: Systematic review and meta‐analysisDigestive Endoscopy, 2020
- Role of endoscopic vacuum therapy in the management of gastrointestinal transmural defectsWorld Journal of Gastrointestinal Endoscopy, 2019
- Endoscopic Full-Thickness Defects and Closure TechniquesCurrent Treatment Options in Gastroenterology, 2018
- Open-pore film drainage (OFD): a new multipurpose tool for endoscopic negative pressure therapy (ENPT)Endoscopy International Open, 2018