MEMBRANE ACTION OF FLOOR SLABS IN FIRE (PART 2): LOAD-BEARING FIRE TESTS OF A FLOORING SYSTEM COMPOSED OF COMPOSITE SLABS AND AN UNPROTECTED STEEL BEAM
Authors:
- 1 July 2022
- journal article
- research article
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 87 (797) , 646-656
Abstract
In the composite slab used for the steel structure, welded wire mesh, which installes for priventing the concrete cracks, acts as the tension reinforcing bars in the fire, and due to membrane action the load bearing capacity can be expected to increase. As a result, there is a possibility that fire protection can be removed from secondary beams. In this paper, the load bearing capacity and ultimate state of composite slab in the fire were examined by carrying out load-bearing fire test to flooring system consists of composite slab and unprotected secondary beam until collapse.Keywords
This publication has 2 references indexed in Scilit:
- MEMBRANE ACTION OF FLOOR SLABS IN FIRE (PART 1): LOAD-BEARING FIRE TESTS OF A COMPOSITE FLOORING SYSTEM COMPOSED OF RC SLABS AND AN UNPROTECTED STEEL BEAMJournal of Structural and Construction Engineering (Transactions of AIJ), 2021
- INFLUENCE OF CURING CONDITION AND WATER CEMENT RATIO ON MECHANICAL PROPERTIES OF CONCRETE IN HIGH TEMPERATURESJournal of Structural and Construction Engineering (Transactions of AIJ), 2016