Acetabular Options: Notes From the Other Side
Authors:
- Keegan AuKAKeegan Au
- Robert B. BourneRBRobert B. Bourne
- 1 September 2009
- journal article
- review article
- Published by SLACK, Inc. in Orthopedics
- Vol. 32 (9) , 664-667
Abstract
The socket remains the weakest link of primary total hip arthroplasty (THA). The revision rates of the socket are higher than those of the stem, with aseptic loosening and polyethylene wear being the most frequent indications for revision THA. Both cemented all-polyethylene cups and cementless sockets have benefited from stepwise improvements in surgical techniques and designs. In many countries, cementless sockets have replaced cemented cups during primary THA, with >90% of the acetabular components using a cementless fixation mode. The long-term prospective data of cementless sockets from high-volume centers show excellent and equivalent survivorship to cemented implants, but the insertion technique is easier and quicker. In addition, cementless sockets are more versatile than cemented all-polyethylene cups. With cementless sockets there is a move to increased porosity of the ingrowth surface, tri-bearing options, and enhanced locking mechanisms. There is a role for well-conducted randomized controlled trials to assess these new designs because data from various national registries show that the socket remains the weakest link of primary THA. Factors like sex, age, diagnosis, and bearing couples have a different and significant influence on the intermediate to long-term survivorship of contemporary cemented and cementless THA.Keywords
This publication has 11 references indexed in Scilit:
- Revision following cemented and uncemented primary total hip replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- Cemented total hip replacement for primary osteoarthritis in patients aged 55 years or olderThe Journal of Bone and Joint Surgery. British volume, 2008
- The Harris-Galante porous-coated, hemispherical, polyethylene-lined acetabular component in patients under 50 years of ageThe Journal of Bone and Joint Surgery. British volume, 2008
- Results of the Anatomic Medullary Locking Total Hip Arthroplasty at a Minimum of Twenty YearsJournal of Bone and Joint Surgery, 2008
- Total Hip Arthroplasty with Cement and Use of a Collared Matte-Finish Femoral ComponentJournal of Bone and Joint Surgery, 2008
- The Twenty to Twenty-five-Year Outcomes of the Harris Design-2 Matte-Finished Cemented Total Hip ReplacementJournal of Bone and Joint Surgery, 2007
- Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-termsThe Journal of Bone and Joint Surgery. British volume, 2006
- Results of Charnley Total Hip Arthroplasty with Use of Improved Femoral Cementing TechniquesJournal of Bone and Joint Surgery, 2006
- Twenty-five-Year Survivorship of Two Thousand Consecutive Primary Charnley Total Hip ReplacementsJournal of Bone and Joint Surgery, 2002
- The Porous Coated Anatomic Total Hip ReplacementJournal of Bone and Joint Surgery, 2001