A microscopic oxygen transport model for ultra‐high dose rate radiotherapy in vivo: The impact of physiological conditions on FLASH effect
Open Access
- 16 September 2024
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 51 (11) , 8623-8637
Abstract
Background: Ultra‐high dose rate irradiation (≥40 Gy/s, FLASH) has been shown to reduce normal tissue toxicity, while maintaining tumor control compared to conventional dose‐rate radiotherapy. The radiolytic oxygen (O2) depletion (ROD) resulting from FLASH has been proposed to explain the normal tissue protection effect; however, in vivo experiments have not confirmed that FLASH induced global tissue hypoxia. Nonetheless, the experiments reported are based on volume‐averaged measurement, which have inherent limitations in detecting microscopic phenomena, including the potential preservation of stem cells niches due to local FLASH‐induced O2 depletion. Computational modeling offers a complementary approach to understand the ROD caused by FLASH at the microscopic level.Purpose: We developed a comprehensive model to describe the spatial and temporal dynamics of O2 consumption and transport in response to irradiation in vivo. The change of oxygen enhancement ratio (OER) was used to quantify and investigate the FLASH effect as a function of physiological and radiation parameters at microscopic scale.Methods: We considered time‐dependent O2 supply and consumption in a 3D cylindrical geometry, incorporating blood flow linking the O2 concentration ([O2]) in the capillary to that within the tissue through the Hill equation, radial and axial diffusion of O2, metabolic and zero‐order radiolytic O2 consumption, and a pulsed radiation structure. Time‐evolved distributions of [O2] were obtained by numerically solving perfusion‐diffusion equations. The model enables the computation of dynamic O2 distribution and the relative change of OER (δROD) under various physiological and radiation conditions in vivo.Results: Initial [O2] level and the subsequent changes during irradiation determined δROD distribution, which strongly depends on physiological parameters, i.e., intercapillary spacing, ultimately determining the tissue area with enhanced radioresistance. We observed that the δROD/FLASH effect is affected by and sensitive to the interplay effect among physiological and radiation parameters. It renders that the FLASH effect can be tissue environment dependent. The saturation of FLASH normal tissue protection upon dose and dose rate was shown. Beyond ∼60 Gy/s, no significant decrease in radiosensitivity within tissue region was observed. In turn, for a given dose rate, the change of radiosensitivity became saturated after a certain dose level. Pulse structures with the same dose and instantaneous dose rate but with different delivery times were shown to have distinguishable δROD thus tissue sparing, suggesting the average dose rate could be a metric assessing the FLASH effect and demonstrating the capability of our model to support experimental findings.Conclusion: On a macroscopic scale, the modeling results align with the experimental findings in terms of dose and dose rate thresholds, and it also indicates that pulse structure can vary the FLASH effect. At the microscopic level, this model enables us to examine the spatially resolved FLASH effect based on physiological and irradiation parameters. Our model thus provides a complementary approach to experimental methods for understanding the underlying mechanism of FLASH radiotherapy. Our results show that physiological conditions can potentially determine the FLASH efficacy in tissue protection. The FLASH effect may be observed under optimal combination of physiological parameters, not limited to radiation conditions alone.Keywords
Funding Information
- Cancer Prevention and Research Institute of Texas (RR200042)
This publication has 60 references indexed in Scilit:
- Modeling of the FLASH effect for ion beam radiation therapyPhysica Medica, 2023
- A potential revolution in cancer treatment: A topical review of FLASH radiotherapyJournal of Applied Clinical Medical Physics, 2022
- 3D computational model of oxygen depletion kinetics in brain vasculature during FLASH RT and its implications for in vivo oximetry experimentsMedical Physics, 2022
- Model studies of the role of oxygen in the FLASH effectMedical Physics, 2021
- Simulations of measured photobleaching kinetics in human basal cell carcinomas suggest blood flow reductions during ALA‐PDTLasers in Surgery and Medicine, 2009
- Distribution of oxygen tension on the surface of arterioles, capillaries and venules of brain cortex and in tissue in normoxia: an experimental study on ratsPflügers Archiv - European Journal of Physiology, 1999
- Microcirculation of the Skin1984
- A digital simulation of transient oxygen transport in capillary‐tissue systems (cerebral grey matter). Development of a numerical method for solution of transport equations describing coupled convection‐diffusion systemsAIChE Journal, 1969
- A Mathematical Simulation of Oxygen Release, Diffusion, and Consumption in the Capillaries and Tissue of the Human Brain1967
- Die Sauerstoffdiffusion im GehirnPflügers Archiv - European Journal of Physiology, 1960