Frequency dependent hysteresis loss in SiFe
Authors:
- 1 November 1982
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 53 (11) , 8299-8301
Abstract
We have studied the hysteresis loss associated with nonmagnetic inclusions that are large enough to support a supplementary domain structure. This tube domain structure interacts with a main domain wall by adhering to it as long as it is near enough to the inclusion. Loss is determined by the difference in stored tube energy between the first contact with the wall and the ultimate loss of contact. Experimentally, the area of contact decreases with increasing elongation of the supplementary structure; in our theory loss of contact occurs when this area goes to zero. The tube length at which the area of contact vanishes is significantly dependent upon the applied field, which itself must increase with increasing frequency as a result of the eddy currents loss associated with motion of the main domain walls. This implies that the tube will break free at differing lengths for differing frequencies. Our calculations show, for example, for one set of observed specimen parameters and a peak magnetization one-half of saturation, that the loss due to this mechanism increases by approximately a factor of 2 between zero frequency and 60 Hz.Keywords
This publication has 5 references indexed in Scilit:
- Domain Tube Structures in Silicon IronProceedings of the Physical Society (1958-1967), 1960
- Calculation of the Energy Loss in Magnetic Sheet Materials Using a Domain ModelJournal of Applied Physics, 1958
- A Study of Surface Closure Domains by the Powder Pattern TechniqueProceedings of the Physical Society. Section A, 1952
- Studies of the Propagation Velocity of a Ferromagnetic Domain BoundaryPhysical Review B, 1950
- A Simple Domain Structure in an Iron Crystal Showing a Direct Correlation with the MagnetizationPhysical Review B, 1949