Disparities in transvenous lead extraction in young adults
Authors:
Open Access
- 10 June 2022
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
Abstract
Adults with cardiac implantable electronic devices (CIEDs) implanted at an early age constitute a specific group of patients undergoing transvenous lead extraction (TLE). The aim of this study is to assess safety and effectiveness of TLE in young adults. A comparative analysis of two groups of patients undergoing transvenous lead extraction was performed: 126 adults who were 19–29 years old at their first CIED implantation (early adulthood) and 2659 adults who were > 40 years of age at first CIED implantation and < 80 years of age at the time of TLE (middle-age/older adulthood). CIED-dependent risk factors were more common in young adults, especially longer implant duration (169.7 vs. 94.0 months). Moreover younger age of patients at first implantation, regardless of the dwell lead time, is a factor contributing to the greater development of connective tissue proliferation on the leads (OR 2.587; p < 0.001) and adhesions of the leads with the heart structures (OR 3.322; p < 0.001), which translates into worse TLE results in this group of patients. The complexity of procedures and major complications were more common in younger group (7.1 vs. 2.0%; p < 0.001), including hemopericardium (4.8 vs 1.3; p = 0.006) and TLE-induced tricuspid valve damage (3.2 vs.0.3%; p < 0.001). Among middle-aged/older adults, there were 7 periprocedural deaths: 6 related to the TLE procedure and one associated with indications for lead removal. No fatal complications of TLE were reported in young adults despite the above-mentioned differences (periprocedural mortality rate was comparable in study groups 0.3% vs 0.0%; p = 0.739). Predictors of TLE-associated major complications and procedure complexity were more likely in young adults compared with patients aged > 40 to < 80 years. In younger aged patients prolonged extraction duration and higher procedure complexity were combined with a greater need for second line tools. Both major and minor complications were more frequent in young adults, with hemopericardium and tricuspid valve damage being predominant.Keywords
This publication has 22 references indexed in Scilit:
- Nomogram for predicting 30-day all-cause mortality after transvenous pacemaker and defibrillator lead extractionHeart Rhythm, 2015
- Predictors of Long-Term Survival Following Transvenous Extraction of Defibrillator LeadsPacing and Clinical Electrophysiology, 2015
- The Fate of Nontargeted Endocardial Leads during the Extraction of One or More Targeted Leads in Pediatrics and Congenital Heart DiseasePacing and Clinical Electrophysiology, 2013
- Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young AdultsCirculation, 2013
- Pediatric and Adult Congenital Endocardial Lead Extraction or Abandonment Decision (PACELEAD) Survey of Lead ManagementPacing and Clinical Electrophysiology, 2011
- Lead Extraction in Pediatric and Congenital Heart Disease PatientsCirculation: Arrhythmia and Electrophysiology, 2010
- Lead removal in young patients in view of lifelong pacingEP Europace, 2010
- Lead Extraction in Children and Young Adults Using Different TechniquesMedical Principles and Practice, 2009
- Transvenous Lead Extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient ManagementHeart Rhythm, 2009
- Effectiveness of Excimer Laser‐Assisted Pacing and ICD Lead Extraction in Children and Young AdultsPacing and Clinical Electrophysiology, 2006