Subtrochanteric Fixation Stability Depends on Discrete Fracture Surface Points
Authors:
- Todd L BredbennerTBTodd L Bredbenner
- Scott A SnyderSSScott A Snyder
- Farzad R MazloomiFMFarzad R Mazloomi
- Toan LeTLToan Le
- Roger G WilberRWRoger G Wilber
- 1 March 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 432 (432) , 217-225
Abstract
Fixation of subtrochanteric femur fractures may present complications, including malunion, delayed union, or nonunion, and is thought to be related to early fracture stability. To examine the initial stability of subtrochanteric fracture fixation, we investigated construct stiffness, interfragmentary gaps, and overall and point-wise interfragmentary motion (ie, axial and shear displacements) in synthetic composite femurs fixed with a cephalomedullary nail or condylar blade plate. Simulated stable and unstable subtrochanteric femur fractures were created in composite femurs, anatomically reduced, fixed with either a long Gamma nail or a blade plate, and subjected to combined axial, bending, and torsional loading. The long Gamma nail group consistently showed greater displacement magnitudes than the blade plate group; these differences included axial and shear displacement magnitudes in the stable fracture group and shear displacement magnitudes in the unstable fracture group. Overall differences in fixation stability were dependent on discrete points around the periphery of the contiguous fracture surfaces, especially in the unstable fracture group. These differences in interfragmentary motion patterns between implant constructs were detected despite the lack of difference in combined axial, bending, and torsional construct stiffness or initial interfragmentary gap.Keywords
This publication has 40 references indexed in Scilit:
- The initial phase of fracture healing is specifically sensitive to mechanical conditionsJournal of Orthopaedic Research, 2003
- The Long Gamma Nail in the Treatment of 329 Subtrochanteric Fractures with Major Extension into the Femoral ShaftBritish Journal of Surgery, 2000
- Influence of size and stability of the osteotomy gap on the success of fracture healingJournal of Orthopaedic Research, 1997
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996
- Influence of thigh muscles on the axial strains in a proximal femur during early stance in gaitJournal of Biomechanics, 1995
- Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysisClinical Materials, 1994
- A review of joint and muscle load simulation relevant to in‐vitro stress analysis of the hipStrain, 1994
- Technical note. Comparison of the deformation response of synthetic and cadaveric femora during simulated one‐legged stanceJournal of Applied Biomaterials, 1991
- Subtrochanteric Femur FracturesJournal of Orthopaedic Trauma, 1991
- A biomechanical comparison of various methods of stabilization of subtrochanteric fractures of the femurJournal of Orthopaedic Research, 1984