Error of a Temperature Probe for Cancer Ablation Monitoring Caused by Respiratory Movements: Ex Vivo and In Vivo Analysis
Open Access
- 1 June 2016
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 16 (15) , 5934-5941
Abstract
Hyperthermal techniques are spreading as an alternative to conventional surgery for cancer removal. A real-time temperature feedback can be used to adjust the treatment settings, in order to improve the clinical outcomes. In this paper, we experimentally assessed the feasibility for distributed temperature monitoring of a custom probe, which consists of a needle embedding six fiber Bragg gratings (FBGs). Since FBGs are also sensitive to strain, we focused on the analysis of the measurement error (artifact) caused by respiratory movements. We assessed the artifact both on ex vivo pig liver and lung (by mimicking the movement of these organs caused by respiration) and on in vivo trial on pig liver. Lastly, we proposed an algorithm to detect and minimize the artifact during ex vivo liver laser ablation. During both ex vivo and in vivo trials, the probe insertion within the organ was easy and safe. The artifact was significant (up to 3 °C), but the correction algorithm allows minimizing the error. The main advantages of the proposed probe are: 1) spatially resolved temperature monitoring (in six points of the tissue by inserting a single needle) and 2) the needle is magnetic resonance (MR)-compatible, hence can be used during MR-guided procedure. Even if the model is close to humans, further trials are required to investigate the feasibility of the probe for clinical applications.Keywords
This publication has 28 references indexed in Scilit:
- Magnetic resonance-based thermometry during laser ablation on ex-vivo swine pancreas and liverMedical Engineering & Physics, 2015
- Fiber-Optic Temperature and Pressure Sensors Applied to Radiofrequency Thermal Ablation in Liver Phantom: Methodology and Experimental MeasurementsJournal of Sensors, 2015
- Assessment of temperature measurement error and its correction during Nd:YAG laser ablation in porcine pancreasInternational Journal of Hyperthermia, 2014
- Monitoring of radiofrequency thermal ablation in liver tissue through fibre Bragg grating sensors arrayElectronics Letters, 2014
- CT-based thermometry: An overviewInternational Journal of Hyperthermia, 2014
- Experimental assessment of CT-based thermometry during laser ablation of porcine pancreasPhysics in Medicine & Biology, 2013
- Theoretical Analysis and Experimental Evaluation of Laser-Induced Interstitial Thermotherapy in Ex Vivo Porcine PancreasIEEE Transactions on Biomedical Engineering, 2012
- Feasibility Study of Ultrasonic Computed Tomography–Guided High-Intensity Focused UltrasoundUltrasound in Medicine & Biology, 2012
- Magnetic resonance temperature imaging for guidance of thermotherapyJournal of Magnetic Resonance Imaging, 2000
- In Situ temperature measurements with thermocouple probes during laser interstitial thermotherapy (LITT): Quantification and correction of a measurement artifactLasers in Surgery and Medicine, 1998