Mass Measurement of $^{27}$P for Improved Type-I X-ray Burst Modeling
Authors:
Preprint
Abstract
Light curves are the primary observable of type-I x-ray bursts. Computational x-ray burst models must match simulations to observed light curves. Most of the error in simulated curves comes from uncertainties in $rp$ process reaction rates, which can be reduced via precision mass measurements of neutron-deficient isotopes in the $rp$ process path. We perform a precise atomic mass measurement of $^{27}$P and use this new measurement to update existing type-I x-ray burst models to produce an improved light curve. High-precision Penning trap mass spectrometry was used to determine the atomic mass of $^{27}$P. Modules for Experiments in Stellar Astrophysics (MESA) was then used to simulate x-ray bursts using a 1D multi-zone model to produce updated light curves. The mass excess of $^{27}$P was measured to be -670.7$\pm$ 0.6 keV, a fourteen-fold precision increase over the mass reported in AME2020. The $^{26}$Si($p, \gamma$)$^{27}$P and reverse photodisintegration reaction rates have been determined to a higher precision based on the new, high precision mass measurement of $^{27}$P, and MESA light curves generated using these rates. Changes in the mass of $^{27}$P seem to have minimal effect on XRB light curves, even in burster systems tailored to maximize impact. The mass of $^{27}$P does not play a significant role in x-ray burst light curves. It is important to understand that more advanced models don't just provide more precise results, but often qualitatively different ones. This result brings us a step closer to being able to extract stellar parameters from individual x-ray burst observations. In addition, the Isobaric Multiplet Mass Equation (IMME) has been validated for the $A=27, T=3/2$ quartet, but only after including a small, theoretically predicted cubic term and utilizing an updated excitation energy for the $T=3/2$ isobaric analogue state of $^{27}$Si.
Keywords
All Related Versions
This publication has 17 references indexed in Scilit:
- Experimentally well-constrained masses of 27P and 27S: Implications for studies of explosive binary systemsPhysics Letters B, 2020
- Beam thermalization in a large gas catcherNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2020
- The LEBIT ion cooler and buncherNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- MODULES FOR EXPERIMENTS IN STELLAR ASTROPHYSICS (MESA): PLANETS, OSCILLATIONS, ROTATION, AND MASSIVE STARSThe Astrophysical Journal Supplement Series, 2013
- The LEBIT 9.4T Penning trap mass spectrometerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Commissioning the A1900 projectile fragment separatorNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2003
- rp-process nucleosynthesis at extreme temperature and density conditionsPhysics Reports, 1998
- The accuracy of heavy-ion mass measurements using time of flight-ion cyclotron resonance in a Penning trapJournal of Applied Physics, 1990
- γ-ray bursts from thermonuclear explosions on neutron starsNature, 1976
- The Calculation of Errors by the Method of Least SquaresPhysical Review B, 1932