Seismic performance evaluation and multiple-support excitation analysis of a 1.26-km viaduct in the Philippines
Authors:
- 1 January 2026
- conference paper
- Published by International Association for Bridge and Structural Engineering (IABSE)
- Vol. 26, 1580-1587
Abstract
This study evaluates the seismic performance of a 1.26-km reinforced concrete viaduct in the Philippines incorporating base isolation. A three-dimensional finite-element model with nonlinear high-damping rubber bearings with lead cores (HDR-LRB) was subjected to nonlinear time-history analyses for Level I (100-year) and Level II (1,000-year) earthquakes. Isolation increased damping and lengthened the fundamental period from 0.65 s to 1.38 s, reducing substructure demands. Under Level II, maximum isolator shear strain (γeq) remained below 200%, while total combined shear strain (γt = 237.7%) was within the 550% limit. Pier displacement ductility demands (0.91 longitudinal, 0.38 transverse) indicate elastic response. Results confirm the effectiveness of the isolation system in limiting seismic demand and maintaining functionality under severe ground motions. Multiple-support excitation resulted in lower structural responses than uniform excitation.This publication has 1 reference indexed in Scilit:
- Seismic fragility and vulnerability assessment of a multi-span irregular curved bridge under spatially varying ground motionsSoil Dynamics and Earthquake Engineering, 2024