Predicting the postoperative intraocular lens position based on IOL Master 700 biometry, compared with results from the anterior segment analysis system
Authors:
- 21 July 2023
- journal article
- research article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 262 (1) , 113-119
Abstract
Purpose Predict intraocular lens position after cataract surgery using the IOL Master 700 and explore the associated ocular parameters compared with the results obtained from the anterior segment analysis system (Sirius, CSO Inc, Florence, Italy). Methods A total of 98 patients (106 eyes) were included in the retrospective study. The postoperative intraocular lens position was obtained using the IOL Master 700 and measured using Adobe Illustrator software. Correlation analysis and linear regression analysis were applied to study the correlation between the actual position of the postoperative intraocular lens (ALP) and the ocular parameters. In addition, Bland–Altman consistency analysis was used to compare the consistency between any two among the predicted intraocular lens position (ALPi) obtained using IOL Master 700 biometry, the predicted artificial lens position (ALPs) calculated using the anterior segment analysis system, or the ALP. Results Ocular parameters, including preoperative anterior chamber depth, lens thickness, axial length, white-to-white, and postoperative refractive error were all correlated with ALP after cataract surgery (P < 0.05) using univariate analysis. However, in multivariate linear regression, only the first three variables were correlated with ALP. Compared with the equation obtained by the anterior segment analysis, the equation from IOL Master 700 biometry provided a better fit. The results of the consistency analysis showed that ALP, ALPi, and ALPs were in good agreement. Conclusion IOL Master 700 biometry can help predict intraocular lens position after surgery, and its accuracy is better than that provided by the anterior segment analysis system.Keywords
Funding Information
- Jiangsu Commission of Health (grant number CXTDA2017039)
This publication has 24 references indexed in Scilit:
- Prevalence of Cataract Surgery and Postoperative Visual Outcome in Greater Beijing: The Beijing Eye StudyOphthalmology, 2009
- Sources of error in intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2008
- Calculation of intraocular lens power: a reviewActa Ophthalmologica Scandinavica, 2007
- Age-related cataractThe Lancet, 2005
- Optical Coherence Biometry2002
- An improved universal theoretical formula for intraocular lens power predictionJournal of Cataract & Refractive Surgery, 1993
- The Hoffer Q formula: A comparison of theoretic and regression formulasJournal of Cataract & Refractive Surgery, 1993
- Occurrence of Erroneous Anterior Chamber Depth in the SRK/T FormulaJournal of Cataract & Refractive Surgery, 1993
- Development of the SRK/T intraocular lens implant power calculation formulaJournal of Cataract & Refractive Surgery, 1990
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988