Direct Dissolution of Nuclear Materials for Chemical Quality Control

Authors:

Abstract
Direct dissolution of uranium carbide was found to be very effective when it was refluxed with an 18 M H2SO4-15 M HNO3 (1:1) mixture. Clear solutions could be obtained within 1 h. Uranium-plutonium carbide, as well as PuO2 could also be dissolved in 1 to 2 h in the same way. Other nuclear materials, UO2 + C and UO2 + PuO2 + C, needed longer duration for complete dissolution. When the proportion of H2SO4 in the H2SO4‾HNO3 mixture was increased to 2:1, these materials also dissolved within 2 h. Quantitativeness of the dissolution was checked by the potentiometric determination of uranium and/or plutonium contents in these solutions. The results were in good agreement (±0.5%) when compared with the values obtained by the well-established dissolution method. During the fabrication of fuel (plutonium-rich mixed carbide) for the fast breeder test reactor, a large number of fuel samples were analyzed by using the above method of dissolution for the chemical quality control. Presuming the possibility of for...

This publication has 7 references indexed in Scilit: