Transvenous Lead Extraction Using Mechanical Rotational Dilator Sheaths: A 19-Year Single-Center Experience from a Pediatric Cardiology Center
Open Access
- 7 June 2026
- journal article
- research article
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 13 (6) , 253
Abstract
The increasing use of cardiac implantable electronic devices (CIEDs) in pediatric and adolescent populations has led to a growing need for transvenous lead extraction (TLE). However, data on long-term outcomes remain limited. This study aimed to evaluate the efficacy and safety of TLE using mechanical rotational dilator sheaths in a pediatric cohort. This retrospective single-center study included 35 patients who underwent TLE between 2007 and 2025. Outcomes were compared between Evolution® (Cook Medical, Bloomington, IN, USA) and TightRail™ (Spectranetics/Philips, Colorado Springs, CO, USA) sheath systems. A total of 40 leads were extracted (mean age at extraction: 15.1 ± 4.2 years; 57% male). The most common indication for extraction was lead fracture/dysfunction (22/35–63%). Complete success with the procedure was achieved in 23 (66%) patients, and clinical success in 30 (86%). Major complications requiring surgery occurred in 5 (14%) patients, and minor complications in 2 (6%). Notably, all major complications occurred in patients with implantable cardioverter-defibrillator (ICD) leads (p = 0.013), including innominate vein injury, pericardial effusion, tricuspid entrapment, and cardiac perforation. A comparison of the Evolution® (n:20) and TightRail™ (n:15) sheath groups showed no statistically significant differences in complete procedural success (p = 0.603), clinical success (p = 0.604), or the incidence of major complications (p = 0.640). No procedure-related mortality was observed. TLE using mechanical rotational dilator sheaths in pediatric patients is feasible and provides acceptable clinical success rates. However, the risk of major complications remains considerable, particularly in patients with ICD leads. These findings highlight the importance of careful procedural planning and performing TLE in experienced centers with immediate surgical backup.Keywords
This publication has 12 references indexed in Scilit:
- Safety and Efficacy of the Novel OmniaSecure Defibrillation Lead Through Long-Term Follow-Up: Final Results From the LEADR TrialCirculation: Arrhythmia and Electrophysiology, 2026
- Conduction System Pacing in Children and Congenital Heart DiseaseArrhythmia and Electrophysiology Review, 2024
- Safety and feasibility of same‐day discharge following uncomplicated transvenous lead extractionJournal of Cardiovascular Electrophysiology, 2023
- Lead Management in Patients with Congenital Heart DiseaseCardiac Electrophysiology Clinics, 2023
- Transvenous lead extraction of lumenless 3830 pacing lead in conduction system pacing: a single-center experienceJournal of Interventional Cardiac Electrophysiology, 2023
- Transvenous Lead Extraction in Pediatric Patients ― Is It the Same Procedure in Children as in Adults? ―Circulation Journal, 2023
- Lead Extraction at a Pediatric/Congenital Heart Disease CenterJACC: Clinical Electrophysiology, 2022
- Comparison of acute and long‐term outcomes of Evolution® and TightRail™ mechanical dilator sheaths during transvenous lead extractionJournal of Cardiovascular Electrophysiology, 2021
- Lead Extraction in Pediatric and Congenital Heart Disease PatientsCirculation: Arrhythmia and Electrophysiology, 2010
- Practical Aspects of Implantable Defibrillator Therapy in Patients with Congenital Heart DiseasePacing and Clinical Electrophysiology, 2008