Abstract
Objective: Extraction and analysis of various clinically significant features of photoplethysmogram (PPG) signals for monitoring several physiological parameters as well as for biometric authentication have become important areas of research in recent years. However, PPG signal compression; particularly quality-guaranteed compression, and steganography of patient's secret information is still lagging behind. Method: This paper presents a robust, reliable and highly-efficient singular value decomposition (SVD) and lossless ASCII character encoding (LL-ACE)-based quality-guaranteed PPG compression algorithm. This algorithm can not only be used to compress PPG signals but also do so for steganographed PPG signals that include the patient information. Result and conclusion: It is worth mentioning that such an algorithm is being proposed for the first time to compress steganographed PPG signals. The algorithm is tested on PPG signals collected from four different databases, and its performance is assessed using both quantitative and qualitative measures. The proposed steganographed PPG compression algorithm provides a compression ratio that is much higher than that provided by other algorithms that are designed to compress the PPG signals only. Significance: (1) the clinical quality of the reconstructed PPG signal can be controlled precisely, (2) the patient's personal information is restored with no errors, (3) high compression ratio, and (4) the PPG signal reconstruction error is neither dependent on the steganographic operation nor on the size of the patient information data.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
This publication has 25 references indexed in Scilit:
- A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion ArtifactsIEEE Transactions on Biomedical Engineering, 2015
- Zonal complexity based measure for lossy compression of photoplethysmogram using delta encoding2015
- A combined application of lossless and lossy compression in ECG processing and transmission via GSM-based SMSJournal of Medical Engineering & Technology, 2014
- Lossless Compression Technique for Real-Time Photoplethysmographic MeasurementsIEEE Transactions on Instrumentation and Measurement, 2014
- Feature Selection Method for Estimating Systolic Blood Pressure Using the Taguchi MethodIEEE Transactions on Industrial Informatics, 2013
- Multiparameter Respiratory Rate Estimation From the PhotoplethysmogramIEEE Transactions on Biomedical Engineering, 2013
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toesJournal of Human Hypertension, 2002
- The weighted diagnostic distortion (WDD) measure for ECG signal compressionIEEE Transactions on Biomedical Engineering, 2000
- Fast interpolation algorithm using FFTElectronics Letters, 1986