Constructing a Digital Twin of the Birdcage Coil in an MR Scanner by Map Matching: For Radio Frequency Heating Evaluation of Implantable Medical Devices
- 6 October 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Abstract
Radio frequency (RF)-induced heating associated with medical implants is a critical concern when performing a magnetic resonance imaging (MRI) scan. The purpose of this study is to construct a “digital twin” of RF coil integrated in an MRI scanner by $B_{1}^{+}$ map matching, reproducing the physical electromagnetic (EM) field, allowing it to be a qualified test environment for heating evaluations. $B_{1}^{+}$ map inside an American Society for Testing Material (ASTM) phantom with various positions was used to characterize the physical EM field. A loaded tuned two-port birdcage body coil model was established to generate the numerical EM field and optimized to minimize the difference between the measured and simulated fields, which was quantified by “mean symmetric mean absolute percentage error” (mSMAPE). The amplitude of the simulated field was normalized to MR sequence labeling. Finally, the average specific absorption rate (SAR) inside the ASTM phantom was measured in a calorimetry experiment and compared to simulation one heated by the pre-established coil. A heating experiment was performed on an insulated cable to further validate the established test environment. The impact of excitation parameters and the port location was investigated. mSMAPE of the optimized field was less than 10%. The difference between the simulated and measured average SAR was 8.5%. $R^{2}$ for the linear regression of the temperature rise and predicted power deposition using the optimized field was 0.993. The digital twin was successfully constructed and verified a sufficiently accurate description of the physical field. The established construction method of the digital twin provides a handy choice for building RF test environment and may create more possibilities for the development of this area.Keywords
Funding Information
- National Key Research and Development Program of China (2021YFC2400201)
- National Natural Science Foundation of China (51777115, 81830033)
- Shenzhen International Cooperative Research Project (GJHZ20180930110402104)
This publication has 51 references indexed in Scilit:
- An analysis of the accuracy of magnetic resonance flip angle measurement methodsPhysics in Medicine & Biology, 2010
- Measurement, simulation and uncertainty assessment of implant heating during MRIPhysics in Medicine & Biology, 2009
- The technology of MRI — the next 10 years?British Journal of Radiology, 2008
- Spatial distribution of RF‐induced E‐fields and implant heating in MRIMagnetic Resonance in Medicine, 2008
- Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer functionJournal of Magnetic Resonance Imaging, 2007
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Experimental validation of hyperthermia SAR treatment planning using MRB1+imagingPhysics in Medicine & Biology, 2004
- Electrodynamics and ultimate SNR in parallel MR imagingMagnetic Resonance in Medicine, 2004
- Shielded open-circuited sample holder for dielectric measurements of solids and liquidsIEEE Transactions on Instrumentation and Measurement, 1998
- Resonant Modes of the Birdcage CoilJournal of Magnetic Resonance, 1997