Abstract
Background:The effect of an intact fibula on rotational stability after a distal tibial fracture has, to the best of our knowledge, not been clearly defined. We designed a cadaver study to clarify our clinical impression that fixation of the fibula with a plate increases rotational stability of distKeywords
This publication has 9 references indexed in Scilit:
- External Fixation of Tibial Plafond Fractures: Is Routine Plating of the Fibula Necessary?Journal of Orthopaedic Trauma, 1998
- The Role of Fibular Fixation in Combined Fractures of the Tibia and Fibula: A Biomechanical InvestigationJournal of Orthopaedic Trauma, 1997
- Formalin fixation strongly influences biomechanical properties of the spineJournal of Biomechanics, 1996
- The Effect of Simulated Tibial Deformities on the Ankle Joint during the Gait CycleFoot & Ankle, 1984
- The Role of the Interosseous Membrane on Tibiofibular WeightbearingFoot & Ankle, 1984
- A study of function after tibial cast bracingInjury, 1983
- Holographic Investigations of the Human Tibiofibular Interosseous MembraneClinical Orthopaedics and Related Research, 1980
- Problems associated with tibial fractures with intact fibulae.Journal of Bone and Joint Surgery, 1980
- The Weight-Bearing Function of the FibulaJournal of Bone and Joint Surgery, 1971