The long-term performance of chronic microelectrode array implants for neural ensemble recording is affected by temporal degradation in signal quality due to several factors including structural changes in the recording surface, electrical responses, and tissue immune reactivity. This study combines the information available from the temporal aggregation of both biotic and abiotic metrics to analyze and quantify the combined effects on long-term performance. Study of a 42-day implant showed there was a functional relationship between the measured impedance and the array neuronal yield. This was correlated with structural changes in the recording sites, microglial activation/degeneration, and elevation of a blood biochemical marker for axonal injury. We seek to elucidate the mechanisms of chronic microelectrode array failure through the study of the combined effects of these biotic and abiotic factors.Keywords
This publication has 20 references indexed in Scilit:
- Corrosion of tungsten microelectrodes used in neural recording applicationsJournal of Neuroscience Methods, 2011
- Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortexBiomaterials, 2010
- Effects of Glial Cells on Electrode Impedance Recorded from Neural Prosthetic Devices In VitroAnnals of Biomedical Engineering, 2010
- Toward a comparison of microelectrodes for acute and chronic recordingsBrain Research, 2009
- Complex impedance spectroscopy for monitoring tissue responses to inserted neural implantsJournal of Neural Engineering, 2007
- Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case studyIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2006
- Hyperphosphorylated neurofilament NF-H is a serum biomarker of axonal injuryBiochemical and Biophysical Research Communications, 2005
- Biomechanical analysis of silicon microelectrode-induced strain in the brainJournal of Neural Engineering, 2005
- Stability of chronic multichannel neural recordings: Implications for a long-term neural interfaceNeurocomputing, 1999
- Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortexIEEE Transactions on Biomedical Engineering, 1992