Kilohertz Macromolecular Crystallography Using an EIGER Detector at Low X-ray Fluxes
Authors:
- Krishna P. KhakurelKKKrishna P. Khakurel
- Shirly EspinozaShirly Espinoza
- Martin SavkoMSMartin Savko
- Vitaly PolovinkinVPVitaly Polovinkin
- Jan DohnalekJDJan Dohnalek
- William ShepardWSWilliam Shepard
- Angelina AngelovaAngelina Angelova
- Janos HajduJHJanos Hajdu
- Jakob AndreassonJAJakob Andreasson
- Borislav AngelovBorislav Angelov
Open Access
Abstract
Time-resolved in-house macromolecular crystallography is primarily limited by the capabilities of the in-house X-ray sources. These sources can only provide a time-averaged structure of the macromolecules. A significant effort has been made in the development of in-house laser-driven ultrafast X-ray sources, with one of the goals as realizing the visualization of the structural dynamics of macromolecules at a very short timescale within the laboratory-scale infrastructure. Most of such in-house ultrafast X-ray sources are operated at high repetition rates and usually deliver very low flux. Therefore, the necessity of a detector that can operate at the repetition rate of the laser and perform extremely well under low flux conditions is essential. Here, we present experimental results demonstrating the usability of the hybrid-pixel detectors, such as Eiger X 1M, and provide experimental proof that they can be successfully operated to collect macromolecular crystallographic data up to a detector frame rate of 3 kHz from synchrotron sources. Our results also show that the data reduction and structural analysis are successful at such high frame rates and fluxes as low as 108 photons/s, which is comparable to the values expected from a typical laser-driven X-ray source.Keywords
Funding Information
- European Regional Development Fund (CZ.02.1.01/0.0/0.0/16_019/0000789 (ADONIS), CZ.02.1.01/0.0/0.0/15_003/0000447 (ELIBIO))
- Grantová Agentura České Republiky (17- 00973S)
- JINR, Dubna, Russia (3+3 program, No. 204, item 27 from 25.03.2020)
- Akademie Věd České Republiky (MSM100101901)
- IBT CAS (RVO: 86652036)
This publication has 44 references indexed in Scilit:
- Fast and accurate data collection for macromolecular crystallography using the JUNGFRAU detectorNature Methods, 2018
- Copper mediated amyloid-β binding to TransthyretinScientific Reports, 2018
- Entering an era of dynamic structural biology…BMC Biology, 2018
- X-ray free-electron lasers: from dreams to realityPhysica Scripta, 2016
- In meso in situserial X-ray crystallography of soluble and membrane proteins at cryogenic temperaturesActa Crystallographica Section D Structural Biology, 2016
- High-brightness table-top hard X-ray source driven by sub-100-femtosecond mid-infrared pulsesNature Photonics, 2014
- EIGER: Next generation single photon counting detector for X-ray applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Femtosecond hard X-ray plasma sources with a kilohertz repetition rateApplied Physics A, 2009
- Microfocus Cu K_? source for femtosecond x-ray scienceOptics Letters, 2005
- Ultrashort 1-kHz laser plasma hard x-ray sourceOptics Letters, 2002