Hand Gesture Recognition Using EGaIn-Silicone Soft Sensors
Open Access
Abstract
Exploiting hand gestures for non-verbal communication has extraordinary potential in HCI. A data glove is an apparatus widely used to recognize hand gestures. To improve the functionality of the data glove, a highly stretchable and reliable signal-to-noise ratio sensor is indispensable. To do this, the study focused on the development of soft silicone microchannel sensors using a Eutectic Gallium-Indium (EGaIn) liquid metal alloy and a hand gesture recognition system via the proposed data glove using the soft sensor. The EGaIn-silicone sensor was uniquely designed to include two sensing channels to monitor the finger joint movements and to facilitate the EGaIn alloy injection into the meander-type microchannels. We recruited 15 participants to collect hand gesture dataset investigating 12 static hand gestures. The dataset was exploited to estimate the performance of the proposed data glove in hand gesture recognition. Additionally, six traditional classification algorithms were studied. From the results, a random forest shows the highest classification accuracy of 97.3% and a linear discriminant analysis shows the lowest accuracy of 87.4%. The non-linearity of the proposed sensor deteriorated the accuracy of LDA, however, the other classifiers adequately overcame it and performed high accuracies (>90%).Keywords
Funding Information
- Dong-A University (-)
This publication has 59 references indexed in Scilit:
- Direct Writing of Gallium‐Indium Alloy for Stretchable ElectronicsAdvanced Functional Materials, 2014
- A novel array of flex sensors for a goniometric gloveSensors and Actuators A: Physical, 2014
- Vision based hand gesture recognition for human computer interaction: a surveyArtificial Intelligence Review, 2012
- Influence of cross-sectional geometry on the sensitivity and hysteresis of liquid-phase electronic pressure sensorsApplied Physics Letters, 2012
- RLSESN‐based PID adaptive control for a novel wearable rehabilitation robotic hand driven by PM‐TS actuatorsInternational Journal of Intelligent Computing and Cybernetics, 2012
- A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity MonitoringSensors, 2010
- Reversibly Deformable and Mechanically Tunable Fluidic AntennasAdvanced Functional Materials, 2009
- Eutectic Gallium‐Indium (EGaIn): A Liquid Metal Alloy for the Formation of Stable Structures in Microchannels at Room TemperatureAdvanced Functional Materials, 2008
- EXPLORING CONDITIONS FOR THE OPTIMALITY OF NAÏVE BAYESInternational Journal of Pattern Recognition and Artificial Intelligence, 2005
- Discriminatory Analysis. Nonparametric Discrimination: Consistency PropertiesInternational Statistical Review, 1989