Reliable Perfusion Maps in Stroke MRI Using Arterial Input Functions Derived From Distal Middle Cerebral Artery Branches
- 1 January 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 41 (1) , 95-101
Abstract
Background and Purpose— Perfusion imaging is widely used in stroke, but there are uncertainties with regard to the choice of arterial input function (AIF). Two important aspects of AIFs are signal-to-noise ratio and bolus-related signal drop, ideally close to 63%. We hypothesized that distal branches of the middle cerebral artery (MCA) provide higher quality of AIF compared with proximal branches. Methods— Over a period of 3 months, consecutive patients with suspected stroke were examined in a 3-T MRI scanner within 24 hours of symptom onset. AIFs were selected manually in M1, M2, and M3 branches of the MCA contralateral to the suspected ischemia. Signal-to-noise ratio and bolus-related signal drop were analyzed. Perfusion maps were created for every patient and mean values at the insular level as well as relative ranges were compared. Results— Mean age of 132 included patients (53 females) was 67.3 years (SD, 14.9) and median National Institutes of Health Stroke Scale was 3 (interquartile range [IQR] 0 to 6). For further analyses, 4 patients were excluded due to discontinuation of scanning or insufficient bolus arrival (signal drop P Conclusion— The level of AIF selection in the MCA has a major impact on reliability and even quantitative parameters of perfusion maps. For better comparison of perfusion maps, the AIF should be defined by selection of distal branches of the MCA contralateral to the suspected ischemia. In future trials involving perfusion imaging, the MCA segment used for the AIF should be specified.Keywords
This publication has 14 references indexed in Scilit:
- Evaluation of an AIF correction algorithm for dynamic susceptibility contrast-enhanced perfusion MRIMagnetic Resonance in Medicine, 2008
- Correcting saturation effects of the arterial input function in dynamic susceptibility contrast-enhanced MRI — a Monte Carlo simulationMagnetic Resonance Imaging, 2007
- Arterial input functions for dynamic susceptibility contrast MRI: Requirements and signal optionsJournal of Magnetic Resonance Imaging, 2005
- Influence of Arterial Input Function on Hypoperfusion Volumes Measured With Perfusion-Weighted ImagingStroke, 2004
- Measuring the arterial input function with gradient echo sequencesMagnetic Resonance in Medicine, 2003
- Signal‐to‐noise ratio effects in quantitative cerebral perfusion using dynamic susceptibility contrast agentsMagnetic Resonance in Medicine, 2002
- The Impact of Peak Saturation of the Arterial Input Function on Quantitative Evaluation of Dynamic Susceptibility Contrast-Enhanced MR StudiesJournal of Computer Assisted Tomography, 2000
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Clinical Outcome in Ischemic Stroke Predicted by Early Diffusion-Weighted and Perfusion Magnetic Resonance Imaging: A Preliminary AnalysisJournal of Cerebral Blood Flow & Metabolism, 1996
- Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effectsMagnetic Resonance in Medicine, 1988