Method for Assessing Brain Changes Associated With Gluteus Maximus Activation
Authors:
- Beth E. FisherBFBeth E. Fisher
- Ya-Yun LeeYLYa-Yun Lee
- Erica A. PitschEPErica A. Pitsch
- Brian MooreBMBrian Moore
- Anna SouthamASAnna Southam
- Timothy D. FawTFTimothy D. Faw
- Christopher M. PowersCPChristopher M. Powers
- 1 April 2013
- journal article
- clinical trial
- Published by Journal of Orthopaedic & Sports Physical Therapy (JOSPT) in Journal of Orthopaedic & Sports Physical Therapy
- Vol. 43 (4) , 214-221
Abstract
Study Design: Reliability study. Objectives: To determine the feasibility and reliability of using transcranial magnetic stimulation (TMS) to assess corticomotor excitability (CE) of the gluteus maximus. Background: Sport-specific skill training targeting greater utilization of the gluteus maximus has been proposed as a method to reduce the incidence of noncontact knee injuries. The use of TMS to assess changes in CE may help to determine training-induced central mechanisms associated with gluteus maximus activation. Methods: Within- and between-day reliability was measured in 10 healthy adults. The CE was measured by stimulating the gluteus maximus “hotspot” at 120% and 150% of motor threshold, while subjects performed a double-leg bridge. An intraclass correlation coefficient (model 2,1), standard error of measurement, and minimal detectable change were calculated to determine the within- and between-day reliability for the following TMS variables: peak-to-peak motor-evoked potential (MEP) amplitudes, cortical silent period, and MEP latency. Results: It is feasible to measure the CE of the gluteus maximus with TMS. The intraclass correlation coefficients for all TMS outcome measures ranged from 0.73 to 0.97. The ranges of minimal detectable change, with respect to mean values for each TMS variable, were larger for MEP amplitude (304.7–585.4 µV) compared to those for cortical silent period duration (25.3–40.8 milliseconds) and MEP latency (1.1–2.1 milliseconds). Conclusion: The present study demonstrated a feasible method for using TMS to measure CE of the gluteus maximus. Small minimal detectable change values for the cortical silent period and MEP latency provide a references for future studies. J Orthop Sports Phys Ther 2013;43(4):214–221. Epub 13 March 2013. doi:10.2519/jospt.2013.4188Keywords
This publication has 37 references indexed in Scilit:
- The latency distribution of motor evoked potentials in patients with multiple sclerosisClinical Neurophysiology, 2012
- Rationale and Implementation of Anterior Cruciate Ligament Injury Prevention Warm-Up Programs in Female AthletesJournal of Strength & Conditioning Research, 2011
- Reliability of transcranial magnetic stimulation-related measurements of tibialis anterior muscle in healthy subjectsClinical Neurophysiology, 2009
- Putting the Brain on the Map: Use of Transcranial Magnetic Stimulation to Assess and Induce Cortical Plasticity of Upper-Extremity MovementPhysical Therapy, 2007
- Variability of motor potentials evoked by transcranial magnetic stimulation depends on muscle activationExperimental Brain Research, 2006
- Chronic neural adaptation induced by long-term resistance training in humansEuropean Journal of Applied Physiology, 2006
- Postexercise facilitation of motor evoked potentials following transcranial magnetic stimulation: A study in normal subjectsMuscle & Nerve, 2002
- Cortical excitability and sleep deprivation: a transcranial magnetic stimulation studyJournal of Neurology, Neurosurgery & Psychiatry, 2001
- Mechanism of the silent period following transcranial magnetic stimulationExperimental Brain Research, 1999
- Optimal Focal Transcranial Magnetic Activation of the Human Motor CortexJournal Of Clinical Neurophysiology, 1992